Outline of D-<strong>BACS</strong> System<br />

16<br />

DIII : Fundamental policy,<br />

Schedule<br />

timer<br />

Unified ON/OFF<br />

controller<br />

Yes: Possible or Available, No: Impossible or non-existent BMS : Depending on BMS manufacturer<br />

intelligent Touch<br />

intelligent Manager III<br />

Remote BACnet<br />

Controller<br />

Controller<br />

TM<br />

LonTalk<br />

Gate-way<br />

TM<br />

Central Remote<br />

Inter-face Controller<br />

Central control device name<br />

Product name or System name iM 128 iM 256 iM 512 iM 768 iM 1024<br />

DMS50<br />

2B51 DMS504B<br />

DCS301<br />

BA61x8 DST301BA<br />

61<br />

DCS302<br />

CA61x2 DCS301<br />

BA61<br />

DCS302<br />

CA61<br />

51<br />

BRC1C62<br />

DMS50<br />

2B51<br />

DAM60<br />

2B51x2 DAM60<br />

2B51x3 DAM60<br />

2B51x4<br />

DAM60<br />

2B51<br />

DCS60<br />

1C51 DAM60<br />

DCS60 2B52<br />

1A52<br />

DCS60<br />

1C51<br />

Hardware Model Name for one system<br />

DAM41<br />

1B51<br />

Function Detail<br />

Push<br />

designated<br />

keys<br />

Push On/Off<br />

button only<br />

Push designated<br />

keys<br />

BMS<br />

7000<br />

times for<br />

one unit<br />

per year<br />

Windows style Input by office computer BMS<br />

Touch panel<br />

application<br />

Operation method<br />

Operation ( On) Group Yes Yes Yes Yes Yes Yes Yes No<br />

Stop (Off) Group Yes Yes Yes Yes Yes Yes Yes No<br />

All connected units Yes<br />

No<br />

Yes Yes Yes<br />

Unified On/Off<br />

Yes<br />

BMS BMS<br />

By Group / Zone Yes Yes No No<br />

Cooling/Heating mode<br />

By Group / Zone Yes Yes Yes Yes Yes No No<br />

setting<br />

Temperature Setting By Group / Zone Yes Yes Yes Yes Yes Yes No No<br />

Filter sign reset By Group / Zone Yes Yes Yes Yes Yes No No<br />

Wind direction By Group / Zone Yes Yes Yes No Yes No No<br />

Fan speed By Group / Zone Yes Yes Yes Yes Yes No No<br />

Yes No No No Yes No No<br />

By Group / Zone ( to be<br />

addressed as of the HRV<br />

Ventilation Mode<br />

2005 model)<br />

Operation setup<br />

Yes No No No Yes No No<br />

By Group / Zone ( to be<br />

addressed as of the HRV<br />

Ventilation Volume<br />

2006 model)<br />

Yes / T1-2 Yes / T1-2 No<br />

T1,T2 &<br />

By<br />

Forced-off<br />

command<br />

By Forced-off<br />

command<br />

Yes / OPDi<br />

Yes / Terminal<br />

Di1-COM<br />

External signal : Non<br />

voltage, Normally open<br />

contact, to Main unit<br />

terminal block with 0.75-<br />

<strong>1.</strong>25mm2 vinyl cable up<br />

to 150 m in length<br />

System Forced Off Input<br />

Forced thermostat Off No No Yes Yes No No No<br />

Yes Yes Yes Yes Yes No No<br />

Permitted or Prohibited<br />

By group/ Zone for On/<br />

Off, Operation mode and<br />

Temperature setting<br />

Individual remote<br />

controller rejection /<br />

acceptance<br />

No No Yes Yes No No No<br />

Centralized control prohibited or permitted : Sub<br />

Group Address Control Operation Rejection