Outline of D-<strong>BACS</strong> System<br />

20<br />

DIII : Fundamental policy,<br />

Schedule<br />

timer<br />

Unified ON/OFF<br />

controller<br />

Yes: Possible or Available, No: Impossible or non-existent BMS : Depending on BMS manufacturer<br />

intelligent Touch<br />

intelligent Manager III<br />

Remote BACnet<br />

Controller<br />

Controller<br />

TM<br />

LonTalk<br />

Gate-way<br />

TM<br />

Central Remote<br />

Inter-face Controller<br />

Central control device name<br />

Product name or System name iM 128 iM 256 iM 512 iM 768 iM 1024<br />

DMS50<br />

2B51 DMS504B<br />

DCS301<br />

BA61x8 DST301BA<br />

61<br />

DCS302<br />

CA61x2 DCS301<br />

BA61<br />

DCS302<br />

CA61<br />

51<br />

BRC1C62<br />

DMS50<br />

2B51<br />

DAM60<br />

2B51x2 DAM60<br />

2B51x3 DAM60<br />

2B51x4<br />

DAM60<br />

2B51<br />

DCS60<br />

1C51 DAM60<br />

DCS60 2B52<br />

1A52<br />

DCS60<br />

1C51<br />

Hardware Model Name for one system<br />

DAM41<br />

1B51<br />

Function Detail<br />

Yes No No No No<br />

Yes / 128 Gps. for<br />

1 setting, 8<br />

settings<br />

Prevention of excessive<br />

temperature increases/deceases<br />

in unmanned rooms ( Cooling<br />

OFF at 4 deg. C below the max.<br />

temp. and heating OFF at 4 deg.<br />

C above the min. temp. in terms of<br />

TEMPERATURE LIMIT<br />

SETTINGS<br />

suction temp. )<br />

Yes Yes No No No No<br />

Fan operation stop in order to<br />

prevent temperature increases<br />

( circulating of a small volume of<br />

refrigerant) during the Heating<br />

mode or thermo Off ( because<br />

there is no Fan Off function)<br />

HEATING<br />

OPTIMIZATION<br />

SETTINGS<br />

Yes Yes Yes Yes Yes<br />

On/Off with using equipment of Di,<br />

Dio unit, ADP<br />

Control of other facilities<br />

No Yes No No No No<br />

Automatic temperature setting to<br />

minimize drastic temperature<br />

differences with the outdoors<br />

SLIDING<br />

TEMPERATURE<br />

SETTINGS<br />

No YES*1 No No No No<br />

Providing control to limit A/C<br />

power consumption to the set<br />

targets<br />

POWER LIMIT<br />

CONTROL<br />

System setup<br />

No Yes No No No No No No<br />

Within the daily interval during the<br />

calendar based seasons, 3<br />

groups of indoor units can be<br />

stopped for a ratio of 10,<br />

20,30,40%, and/or 2 outdoor units<br />

can be lowered for the capacity<br />

for a ratio of 40, 70%<br />

ECO MODE<br />

No YES, the same as *1 No Yes No No No<br />

Shift of the set temperature by 2<br />

degree<br />

Energy efficiency<br />

No Yes No BMS BMS No No No<br />

An office PC can receive<br />

telephone remote monitor of error<br />

Watch DOG<br />

messages from the iM PC.<br />

No Yes No BMS BMS No No No<br />

An office remote PC can control<br />

and monitor the iM monitoring PC<br />

via public phone lines.<br />

Remote intelligent<br />

Manager<br />

Interlocking Yes Yes/100 links No BMS BMS No No No