DIII : Fundamental policy,<br />

Schedule<br />

timer<br />

Unified ON/OFF<br />

controller<br />

Yes: Possible or Available, No: Impossible or non-existent BMS : Depending on BMS manufacturer<br />

intelligent Touch<br />

intelligent Manager III<br />

Remote BACnet<br />

Controller<br />

Controller<br />

TM LonTalk<br />

Gate-way<br />

TM Central Remote<br />

Inter-face Controller<br />

Central control device name<br />

Product name or System name iM 128 iM 256 iM 512 iM 768 iM 1024<br />

DMS50<br />

2B51 DMS504B<br />

DCS301<br />

BA61x8 DST301BA<br />

61<br />

DCS302<br />

CA61x2 DCS301<br />

BA61<br />

DCS302<br />

CA61<br />

51<br />

BRC1C62<br />

DMS50<br />

2B51<br />

DAM60<br />

2B51x2 DAM60<br />

2B51x3 DAM60<br />

2B51x4<br />

DAM60<br />

2B51<br />

DCS60<br />

1C51 DAM60<br />

DCS60 2B52<br />

1A52<br />

DCS60<br />

1C51<br />

Hardware Model Name for one system<br />

DAM41<br />

1B51<br />

Function Detail<br />

Fire Emergency Stop program No but T1-T2 Yes/32 programs BMS BMS No but T1-T2 No but T1-T2 No but T1-T2<br />

Power failure and recovery processing control?? No Yes BMS BMS No No No<br />

Yes Yes BMS BMS No No No<br />

The 10 most recent<br />

breakdown are saved for<br />

each group/zone. The<br />

500 most recent control<br />

entries are saved.<br />

History Display<br />

Touch Panel Calibration<br />

when touch panel is not<br />

Yes No (Depending on PC) No No No<br />

recognized anymore<br />

Version information Yes Yes No No No<br />

No Yes BMS BMS No No No<br />

Temperature, power<br />

consumption, operation<br />

time, etc.<br />

Graphical report<br />

System setup<br />

No Yes No BMS BMS No No No<br />

Option, screen<br />

configuration system with<br />

the actual layout of the<br />

building<br />

Visual Navigation<br />

No Yes No BMS BMS No No No<br />

No Yes No BMS BMS No No No<br />

No Yes No No No No<br />

action on/off after 2<br />

TIMER EXTENSION<br />

hours by indoor unit<br />

Cumulated Running Time and Cumulated start/stop<br />

Count<br />

Automatic Inspection of Meters indicating pulses of<br />

electrical power, water or gas amount<br />

Measuring<br />

No No No No No No<br />

Presence of function or<br />

DCS002C51 Yes<br />

Necessary option<br />

Record retention period 13 months iPU : 2days / PC: dependant of PC<br />

No. of Wattmeter<br />

3 ports<br />

18<br />

18+19+ 18+19+<br />

18<br />

18+19<br />

connection port<br />

Pi1, Pi2, Pi3 OPDi<br />

19 19+ 19<br />

Power Proportional<br />

Distribution ( P.P.D.)<br />

Yes<br />

Outline of D-<strong>BACS</strong> System<br />

Yes<br />

plus UPS, HUB<br />

Local supplied equipment<br />

like Electric power meter<br />

with pulse output +<br />

personal computer<br />

Web function Yes No No BMS BMS No No No<br />

21