Outline of D-<strong>BACS</strong> System<br />
6. Central Control Equipment Combinations<br />
22<br />
The table below shows which combinations of central control equipment are possible and which are not.<br />
∗1 The schedule timer cannot be used by itself. Use in combination with the central remote controller or unified ON / OFF<br />
controller.<br />
∗2 May be used in combination if control range differs<br />
(up to 8 units: Up to 16 units in the double central control mode).<br />
∗3 Control range should be changed.<br />
(up to 2 units: Up to 4 units in the double central control mode).<br />
∗4 BACnet is available for only monitoring.<br />
� If using in combination with central control equipment, the relation between them is last command priority.<br />
� If using in combination with central control equipment, the remote control mode is decided by the setting of the highest<br />
priority item in the priority rank shown in the table below.<br />
Priority Ranking of Remote Control Mode Settings<br />
<br />
intelligent<br />
Manager<br />
Interface for use<br />
in<br />
LONWORKS ®<br />
Interface for<br />
use in<br />
BACnet ®<br />
Central<br />
Controller<br />
intelligent<br />
Touch<br />
Controller<br />
Unified<br />
ON / OFF<br />
Schedule<br />
Timer<br />
DAM602B51/52 DMS504B51 DMS502B51 DCS302CA61 DCS601C51 DCS301BA61 DST301BA61<br />
intelligent Manager NG NG NG*4 OK OK OK NG<br />
Interface for use in<br />
LONWORKS ® NG NG NG OK OK OK NG<br />
Interface for use in<br />
BACnet ® NG*4 NG NG OK OK OK NG<br />
Central Controller OK OK OK NG*3 OK OK OK<br />
intelligent Touch<br />
Controller<br />
OK OK OK OK OK OK NG<br />
Unified ON/OFF OK OK OK OK OK NG*2 OK<br />
Schedule Timer ∗1 NG NG NG OK NG OK NG<br />
Priority<br />
Ranking<br />
intelligent<br />
Manager III<br />
Maximum number of<br />
connections<br />
Interface for<br />
use in<br />
LONWORKS ®<br />
Interface for<br />
use in<br />
BACnet ®<br />
Parallel<br />
Interface<br />
Central<br />
Remote<br />
Controller<br />
intelligent<br />
Touch<br />
Controller<br />
Unified ON/<br />
OFF<br />
Controller<br />
Schedule<br />
Timer<br />
1 1 1 1 2 2 3 4<br />
BACnet ®<br />
LONWORKS ®<br />
intelligent<br />
Manager III<br />
1<br />
Upper Upper-middle Middle Lower<br />
DIII<br />
Sub<br />
intelligent Touch Controller<br />
Central remote controller<br />
Main<br />
intelligent Touch Controller<br />
Central remote controller<br />
1 (2)<br />
1 (2)<br />
2 (4)<br />
Sub<br />
ON/OFF<br />
controller<br />
Main<br />
ON/OFF<br />
controller<br />
4 (8)<br />
4 (8)<br />
8 (16)<br />
Schedule<br />
Timer<br />
Values in ( ) indicate total numbers including both Main and Sub.<br />
0<br />
1<br />
1