1. D-BACS - Daikin
1. D-BACS - Daikin
1. D-BACS - Daikin
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
DIII : Fundamental policy,<br />
Schedule<br />
timer<br />
Unified ON/OFF<br />
controller<br />
Yes: Possible or Available, No: Impossible or non-existent BMS : Depending on BMS manufacturer<br />
intelligent Touch<br />
intelligent Manager III<br />
Remote BACnet<br />
Controller<br />
Controller<br />
TM<br />
LonTalk<br />
Gate-way<br />
TM<br />
Central Remote<br />
Inter-face Controller<br />
Central control device name<br />
Product name or System name iM 128 iM 256 iM 512 iM 768 iM 1024<br />
DMS50<br />
2B51 DMS504B<br />
DCS301<br />
BA61x8 DST301BA<br />
61<br />
DCS302<br />
CA61x2 DCS301<br />
BA61<br />
DCS302<br />
CA61<br />
51<br />
BRC1C62<br />
DMS50<br />
2B51<br />
DAM60<br />
2B51x2 DAM60<br />
2B51x3 DAM60<br />
2B51x4<br />
DAM60<br />
2B51<br />
DCS60<br />
1C51 DAM60<br />
DCS60 2B52<br />
1A52<br />
DCS60<br />
1C51<br />
Hardware Model Name for one system<br />
DAM41<br />
1B51<br />
Function Detail<br />
To restrict persons<br />
responsible for control Yes / 1 Yes / 30 No<br />
operations / No. of PW<br />
Password (PW) Setup<br />
BMS BMS No No No<br />
To restrict operation of<br />
monitoring screens / No. Yes / 1<br />
of PW<br />
Time zone setup & Time setup (according to area,<br />
Yes Yes No Set time zone BMS No No No<br />
summer time, time of day)<br />
Backlight Setup Auto Off function Yes No (depending on PC) No No No<br />
Names and upper/lower<br />
Group Setup<br />
Yes Yes No BMS BMS No No No<br />
temp. setting<br />
Zone Setup Zone setting Yes Yes No Yes No No<br />
weekly / By group / zone Yes Yes No BMS BMS No No (Yes)<br />
Yes Yes No BMS BMS No No No<br />
Daily setting for a year<br />
(13 months) / By group /<br />
zone<br />
Yes Yes No BMS BMS No No No<br />
Each day (time, minute) /<br />
By group / zone<br />
System setup<br />
Schedule setup<br />
Yes Yes BMS BMS No No No<br />
Types of days<br />
schedulable : ex:Sun-Sat<br />
+ Special day 1-10 = 17<br />
types in total<br />
16 20 BMS BMS 4 No 4<br />
8 128 BMS BMS 8 No 8<br />
No. of time settings for<br />
each day set<br />
No. of the abovementioned<br />
schedule<br />
settings<br />
Yes / 128 Gp. Yes No No No<br />
For locations where the<br />
temperature difference<br />
during the day at night is<br />
very large / No. of<br />
Groups<br />
CHANGE OVER<br />
SETTINGS<br />
Outline of D-<strong>BACS</strong> System<br />
19