The titanium housing is polymerized <strong>with</strong> suitable self-curing polymer in<br />
accordance <strong>with</strong> <strong>the</strong> manufacturer's instructions. We recommend wetting<br />
<strong>the</strong> titanium housing <strong>with</strong> acrylic. The denture is <strong>the</strong>n inserted, <strong>the</strong> exact fit<br />
checked and <strong>the</strong> perforations filled <strong>with</strong> acrylic. After <strong>the</strong> acrylic has cured,<br />
<strong>the</strong> denture is removed from <strong>the</strong> mouth, acrylic overages removed and polished.<br />
The black processing replacement males are <strong>the</strong>n removed and replaced by<br />
corresponding replacement males as described in "Integration of <strong>the</strong> colored<br />
replacement males" on page 58. The finished pros<strong>the</strong>sis is inserted and <strong>the</strong><br />
occlusion checked.<br />
HYBRID RESTORATIONS WITH THE <strong>CAMLOG</strong> ® IMPLANT SYSTEM<br />
EXCHANGE OF THE REPLACEMENT MALES<br />
IN AN EXISTING FULL DENTURE<br />
The Locator ® instrument is used to replace <strong>the</strong> replacement males if needed.<br />
The screw-on tip is turned three rotations counter-clockwise. Press <strong>the</strong><br />
retentive tip into <strong>the</strong> replacement male and remove <strong>the</strong> male.<br />
The middle piece of <strong>the</strong> Locator ® instrument is used to integrate <strong>the</strong> colored<br />
replacement males in <strong>the</strong> empty titanium housing. The tip of <strong>the</strong> instrument<br />
is unscrewed, <strong>the</strong> replacement males positioned and pressed into <strong>the</strong> titanium<br />
housing.<br />
NOTE<br />
The titanium inserts have no friction on <strong>the</strong> middle piece. Therefore,<br />
keep <strong>the</strong> middle piece perpendicular and press in <strong>the</strong> replacement males<br />
from <strong>the</strong> basal view.<br />
See also "Integration of <strong>the</strong> colored replacement males" on page 58.<br />