Performance Requirements<br />

System Level Parameters<br />

HVAC Distribution System<br />

Structural Frame System<br />

Lighting System<br />

Floor Construction System<br />

<strong>Suspended</strong> <strong>Ceiling</strong> System<br />

Thermal Performance<br />

Lighting Performance<br />

Structural Safety<br />

Aesthetics/Appearance<br />

Operational/Maintenance Performance<br />

Spatial Fit<br />

Privacy<br />

Services Equipment Maintenance Req.<br />

Space Function<br />

Floor Area<br />

Building Structure Layout<br />

Beam Depth<br />

Floor Structure<br />

<strong>Suspended</strong> <strong>Ceiling</strong> Type<br />

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43<br />

Thermal Performance 1 1<br />

Lighting Performance 2 2<br />

Structural Safety 3 3<br />

Aesthetics/Appearance 4 4<br />

Operational/Maintenance Performance 5 5<br />

Spatial Fit 6 6<br />

Privacy 7 7<br />

Services Equipment Maintenance Req. 8 1 8 1<br />

Space Function 9 1 1 1 1 1 9<br />

Floor Area 10 1 1 10 1<br />

Building Structure Layout 11 1 1 1 11<br />

Beam Depth 12 1 1 12 1 1<br />

Floor Structure 13 1 1 1 13 1 1 1 1<br />

<strong>Suspended</strong> <strong>Ceiling</strong> Type 14 1 1 1 1 1 1 14 1<br />

HVAC Distribution Layout 15 1 1 1 1 1 15 1 1 1 1<br />

Air Diffuser Quantity 16 1 1 1 16 1<br />

Air Duct Width and Length 17 1 1 1 1 17<br />

Required Depth for HVAC Equipment 18 1 1 1 18<br />

Required Depth for Lighting Equipment 19 1 19 1<br />

Structural Element Connection Details 20 1 1 20 1<br />

HVAC Equipment and Superstructure Integration Scheme 21 1 1 1 1 1 1 21 1<br />

Plenum Depth 22 1 1 1 1 1 1 1 22<br />

Floor to <strong>Ceiling</strong> Height 23 1 1 1 1 1 1 1 1 1 23<br />

<strong>Suspended</strong> <strong>Ceiling</strong> Structural Grid Layout 24 1 1 1 1 24<br />

Panel Width and Length 25 1 1 25<br />

Panel Edge and Joint Detail 26 1 1 1 1 26<br />

Panel Weight 27 1 1 27<br />

Lighting Fixture Quantity 28 1 1 1 1 28<br />

Lighting Fixture Width and Length 29 1 1 29<br />

Lighting Fixture Layout 30 1 1 1 1 1 1 1 30 1<br />

Lighting Fixture Weight 31 1 31 1<br />

Air Diffuser Layout 32 1 1 1 1 32<br />

Air Diffuser Width and Length 33 1 1 1 33<br />

Air Diffuser Weight 34 1 34 1<br />

Load Test Data 35 1 1 1 1 35<br />

Main Runner and Cross Tee Web Height 36 1 1 1 1 1 1 1 1 36<br />

Main Runner and Cross Tee Face Dimension 37 1 1 1 1 1 1 1 1 37<br />

Maximum Lighting Fixture Weight 38 1 1 1 1 1 38 1<br />

Maximum Air Diffuser Weight 39 1 1 1 1 1 39 1<br />

Main Runner and Cross Tee Weight 40 1 1 1 1 40<br />

<strong>Suspended</strong> <strong>Ceiling</strong> Structure-Lighting Fixture Connection Detail 41 1 1 1 1 41<br />

<strong>Suspended</strong> <strong>Ceiling</strong> Structure-Air Diffuser Connection Detail 42 1 1 1 1 42<br />

Hanger Spacings 43 1 1 1 1 1 43<br />

HVAC Distribution Layout<br />

Air Diffuser Quantity<br />

Air Duct Width and Length<br />

Required Depth for HVAC Equipment<br />

Required Depth for Lighting Equipment<br />

Structural Element Connection Details<br />

HVAC Equipment and Superstructure Integration Scheme<br />

Plenum Depth<br />

Floor to <strong>Ceiling</strong> Height<br />

<strong>Suspended</strong> <strong>Ceiling</strong> Structural Grid Layout<br />

Figure 6.12: Initial Parameter-based DSM of <strong>Suspended</strong> <strong>Ceiling</strong> <strong>Design</strong> at System Level<br />

Panel Width and Length<br />

Panel Edge and Joint Detail<br />

Panel Weight<br />

Lighting Fixture Quantity<br />

Lighting Fixture Width and Length<br />

Lighting Fixture Layout<br />

Lighting Fixture Weight<br />

Air Diffuser Layout<br />

Air Diffuser Width and Length<br />

Air Diffuser Weight<br />

Load Test Data<br />

Main Runner and Cross Tee Web Height<br />

Main Runner and Cross Tee Face Dimension<br />

Maximum Lighting Fixture Weight<br />

Maximum Air Diffuser Weight<br />

Main Runner and Cross Tee Weight<br />

<strong>Suspended</strong> <strong>Ceiling</strong> Structure-Lighting Fixture Connection Detai<br />

<strong>Suspended</strong> <strong>Ceiling</strong> Structure-Air Diffuser Connection Detail<br />

Hanger Spacings

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!