HEMPADUR 15570<br />

APPLICATION INSTRUCTIONS<br />

For <strong>product</strong> description refer to the <strong>product</strong> <strong>data</strong> sheet<br />

HEMPADUR®15570<br />

CURING AGENT 95570<br />

Physical <strong>data</strong> Drying time and recoating interval vary with film thickness, temperature and later<br />

versus temperature: exposure conditions, thus: In-field application:<br />

(100 micron/4 mils dry film thickness of HEMPADUR 15570)<br />

Surface temperature<br />

Drying time, approx<br />

Curing time, approx<br />

Atmospheric, medium<br />

Atmospheric, severe<br />

Atmospheric, medium<br />

Atmospheric, severe<br />

Immersion**<br />

Interval for recoating with<br />

HEMPATEX HI-BUILDs<br />

Atmospheric, medium<br />

Atmospheric, severe<br />

Interval for recoating with<br />

58030<br />

Atmospheric, medium<br />

Atmospheric, severe<br />

Interval for recoating with<br />

HEMPADUR qualities<br />

Atmospheric, medium<br />

Atmospheric, severe<br />

Immersion***<br />

Interval for recoating with<br />

HEMPATHANE qualities<br />

Atmospheric<br />

Medium<br />

Severe<br />

Issued: October 1999<br />

-10°C/14°F<br />

36 hours<br />

2 months<br />

18 hours<br />

36 hours<br />

Interval for recoating with<br />

HEMPADUR and HEMPATHANE qualities<br />

36 hours<br />

36 hours<br />

3 days<br />

3 days<br />

2 days<br />

Not relevant<br />

Not relevant<br />

None<br />

None<br />

(90 days)<br />

90 days<br />

27 days<br />

0°C/32°F<br />

16 hours<br />

1 month<br />

9 hours<br />

18 hours<br />

18 hours<br />

18 hours<br />

36 hours<br />

MAXIMUM recoating interval related to later conditions of exposure:<br />

36 hours<br />

23 hours<br />

Not relevant<br />

Not relevant<br />

None<br />

None<br />

(90 days)<br />

45 days<br />

14 days<br />

10°C/50°F<br />

8 hours<br />

14 days<br />

MINIMUM recoating interval related to later conditions of exposure:<br />

Interval for recoating with<br />

HEMPATEX HI-BUILDs and 58030 (10°C/50°F or higher in the case of 58030)<br />

4 hours<br />

8 hours<br />

8 hours<br />

8 hours<br />

16 hours<br />

16 hours<br />

10 hours<br />

6 days<br />

3 days<br />

None<br />

None<br />

60 days<br />

20 days<br />

6 days<br />

20°C/68°F<br />

4 hours<br />

7 days<br />

2 hours<br />

4 hours<br />

4 hours<br />

4 hours<br />

8 hours<br />

8 hours<br />

5 hours<br />

3 days<br />

1½ days<br />

None<br />

None<br />

30 days<br />

10 days<br />

3 days<br />

** NOT relevant for HEMPATHANE Qualities.<br />

*** Depending on actual local conditions, extended maximum recoating intervals may apply.<br />

Please contact HEMPEL for further advice.<br />

Furthermore, please see page 2.<br />

1/2<br />

30°C/86°F<br />

3 hours<br />

5 days<br />

1½ hours<br />

3 hours<br />

3 hours<br />

3 hours<br />

6 hours<br />

6 hours<br />

4 hours<br />

1½ days<br />

1 days<br />

None<br />

None<br />

23 days<br />

5 days<br />

1½ days