hempel product data sheets
hempel product data sheets
hempel product data sheets
- TAGS
- hempel
- liqundiet.com
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
HEMPADUR 15570<br />
Workshop application:<br />
(75 micron/3 mils dry film thickness of HEMPADUR 15570)<br />
Surface temperature<br />
Drying time, approx<br />
Curing time, approx<br />
MINIMUM recoating interval related to later conditions of exposure:<br />
Interval for recoating with<br />
HEMPATEX HI-BUILDs<br />
58030<br />
Atmospheric, medium<br />
Atmospheric, severe<br />
Interval for recoating with<br />
HEMPADUR and HEMPATHANE qualities<br />
Atmospheric, medium<br />
Atmospheric, severe<br />
Immersion*<br />
10°C/50°F<br />
4 hours<br />
14 days<br />
30 minutes<br />
4 hours<br />
4 hours<br />
4 hours<br />
16 hours<br />
* NOT relevant for HEMPATHANE Qualities<br />
20°C/68°F<br />
2 hours<br />
7 days<br />
15 minutes<br />
2 hours<br />
2 hours<br />
2 hours<br />
8 hours<br />
30°C/86°F<br />
1½ hours<br />
5 days<br />
10 minutes<br />
1½ hours<br />
1½ hours<br />
1½ hours<br />
6 hours<br />
Maximum recoating intervals according to preceding table, page 1.<br />
Maximum recoating intervals:<br />
If the maximum recoating interval is exceeded, whatever the subsequent coat,<br />
roughening of the surface is necessary to ensure optimum intercoat adhesion or in the<br />
case of recoating with coatings other than HEMPADUR, apply a (thin) additional coat of<br />
HEMPADUR 15570 within the above directions for recoating.<br />
Long recoating intervals:<br />
A completely clean surface is mandatory to ensure intercoat adhesion, especially in the<br />
case of long recoating intervals. Any dirt, oil and grease have to be removed with eg<br />
suitable detergent followed by high pressure fresh water cleaning. Salts to be removed<br />
by fresh water hosing.<br />
Any degraded surface layer, as a result of a long exposure period, must be removed<br />
as well. Water jetting may be relevant to remove any degraded surface layer and may<br />
also replace the above-mentioned cleaning methods when properly executed. Consult<br />
HEMPEL for specific advice if in doubt.<br />
To check whether the quality of the surface cleaning is adequate, a test patch may be<br />
relevant.<br />
The short minimum recoating intervals when overcoated with 46330, 46370, 46410<br />
and 58030, HEMPADUR and HEMPATHANE in case of workshop application, are only<br />
possible if the finished paint system is through dry before exposure to the environment.<br />
Before recoating after exposure in contaminated environment, irrespective of recoating<br />
interval, clean surface thoroughly e.g. by (high pressure) fresh water hosing and allow to<br />
dry.<br />
Safety: Handle with care. Before and during use, observe all safety labels on packaging and<br />
paint containers, consult HEMPEL Material Safety Data Sheets and follow all local or<br />
national safety regulations. This goes for personal protection such as, but not limited<br />
to, protection of lungs, eyes and of the skin, medical treatment in case of swallowing<br />
the paint or in case of other direct contact with the paint. Take necessary precautions<br />
against possible risks of fire or explosions as well as protection of the environment.<br />
Apply only in well ventilated areas and ensure that adequate forced ventilation exists<br />
when applying paint in confined spaces or when the air is stagnant.<br />
Issued: October 1999 - 1557012430CO007<br />
HEMPEL’S MARINE PAINTS A/S<br />
This Product Data Sheet supersedes those previously issued. For definition and scope, see explanatory notes to<br />
applicable Product Data Sheets.<br />
Data, specifications, directions and recommendations given in this <strong>data</strong> sheet represent only test results or experience<br />
obtained under controlled or specially defined circumstances. Their accuracy, completeness or appropriateness under<br />
the actual conditions of any intended use of the Products herein must be determined exclusively by the Buyer and/or<br />
Issued: User. The Products are supplied October and all technical 1999 assistance is given subject to HEMPEL's GENERAL CONDITIONS OF<br />
SALES, DELIVERY AND SERVICE, unless otherwise expressly agreed in writing. The Manufacturer and Seller disclaim,<br />
and Buyer and/or User waive all claims involving, any liability, including but not limited to negligence, except as<br />
expressed in said GENERAL CONDITIONS for all results, injury or direct or consequential losses or damages arising from<br />
the use of the Products as recommended above, on the overleaf or otherwise.<br />
Product <strong>data</strong> are subject to change without notice and become void five years from the date of issue.<br />
2/2