HEMPEL’S ENAMEL 55850<br />

CURING AGENT 97550<br />

Description: HEMPEL’S ENAMEL 55850 is a two-component oxiraneester based topcoat. Resistant<br />

to splashes of petrol, mineral oils, and mild acids. VOC-compliant.<br />

Recommended use: As a finishing coat in two-pack anti-corrosive systems where safety rules preclude the<br />

use of isocyanate cured paints. In moderately to severely atmospheric environments.<br />

Service temperatures: Maximum, dry: 140°C/282°F.<br />

Availability: Part of Group Assortment. Local availability subject to confirmation.<br />

PHYSICAL CONSTANTS:<br />

Colours/Shade nos: White/10000*<br />

Finish: Glossy<br />

Volume solids, %: 64 ± 1<br />

Theoretical spreading rate: 10.7 m²/litre - 60 micron<br />

428 sq.ft./US gallon - 2.4 mils<br />

Flash point: 43°C/105°F<br />

Specific gravity: 1.4 kg/litre<br />

11.7 lbs/US gallon<br />

Surface dry: 3 (approx.) hours at 20°C/68°F (ISO 1517)<br />

Dry to touch: 8-10 hours at 20°C/68°F<br />

Fully cured: 7 days at 20°C/68°F<br />

V.O.C.: 340 g/litre - 2.8 lbs/US gallon<br />

The physical constants stated are nominal <strong>data</strong> according to the HEMPEL Group's approved formulas. They are subject<br />

to normal manufacturing tolerances and where stated, being standard deviation according to ISO 3534-1.<br />

Further reference is made to "Explanatory Notes" in the HEMPEL Book.<br />

APPLICATION DETAILS:<br />

Mixing ratio for 55850: Base 55859 : Curing agent 97550<br />

2 : 1 by volume<br />

Application method: Airless spray Air spray Brush<br />

Thinner (max.vol.): 08080 (5%) 08080 (15%) 08080 (5%)<br />

Pot life: 8 hours (20°C/68°F)<br />

Nozzle orifice: .018"-.021"<br />

Nozzle pressure: 175 bar/2500 psi<br />

(Airless spray <strong>data</strong> are indicative and subject to adjustment)<br />

Cleaning of tools: THINNER 08080<br />

Indicated film thickness, dry: 60 micron/2.4 mils<br />

Indicated film thickness, wet: 100 micron/4 mils<br />

Recoat interval, min: 24 hours (20°C/68°F)<br />

Recoat interval, max: See REMARKS overleaf<br />

Safety: Handle with care. Before and during use, observe all safety labels on packaging and<br />

paint containers, consult HEMPEL Material Safety Data Sheets and follow all local or<br />

national safety regulations. This goes for personal protection such as, but not limited<br />

to, protection of lungs, eyes and of the skin, medical treatment in case of swallowing<br />

the paint or in case of other direct contact with the paint. Take necessary precautions<br />

against possible risks of fire or explosions as well as protection of the environment.<br />

Apply only in well ventilated areas and ensure that adequate forced ventilation exists<br />

when applying paint in confined spaces or when the air is stagnant.<br />