13.2. Notes for using FFT<br />
* If desired, use the zoom feature to magnify the FFT waveform.<br />
* Use the default dB scale to see a detailed view of multiple frequencies, even if they have very different<br />
amplitudes. Use the Vrms scale to see an overall view of how all frequencies compare to each other.<br />
* Signals that have a DC component or offset can cause incorrect FFT waveform component magnitude<br />
values. To minimize the DC component, choose AC Coupling on the source signal.<br />
* To reduce random noise and aliased components in repetitive or single-shot events, set the oscilloscope<br />
acquisition mode to average.<br />
13.3. Nyquist frequency<br />
The highest frequency that any Real Time <strong>Digital</strong> Oscilloscope can measure is exactly half of the sampling rate<br />
under the condition of no mistakes, which is called Nyquist frequency. If under-sampling occurs when the<br />
frequency sampled is higher than Nyquist frequency, “False Wave” phenomenon will appear. So pay more<br />
attention to the relation between the frequency being sampled and measured.<br />
Note:<br />
In FFT mode, the following settings are prohibited:<br />
1. Window set;<br />
2. XY Format in Display SET;<br />
3. “SET 50%” (the triggering level at the vertical point of signal amplitude) in Trigger setting;<br />
4. Measure.<br />
14. Application of VERTICAL POSITION and VOLTS/DIV Knobs<br />
1. The VERTIVAL POSITION knob is used to adjust the vertical positions of the waveforms of all Channels<br />
(including those resulted from the mathematical operation).The analytic resolution of this control knob<br />
changes with the vertical division.<br />
2. The VOLTS/DIV knob is used to regulate the vertical resolution of the wave forms of all channels<br />
(including those obtained from the mathematical manipulation), which can determine the sensitivity of the<br />
vertical division with the sequence of 1-2-5. The vertical sensitivity goes up when the knob is rotated<br />
clockwise and goes down when the knob is rotated anticlockwise.<br />
3. When the vertical position of the channel waveform is adjusted, the screen shows the information<br />
concerning the vertical position at the lower left corner (see Fig. 24).<br />