Operating Instructions Chapter 11<br />

<strong>CLV63x</strong> <strong>Bar</strong> <strong>Code</strong> <strong>Scanner</strong><br />

Appendix<br />

Parameter value set<br />

Data set which is used to initialise and activate the implemented functions of the bar code<br />

scanner. Transferred using the upload (all parameter values only) or download from the bar<br />

code scanner SOPAS-ET configuration software or vice versa.<br />

Raster scanner<br />

<strong>Scanner</strong> that uses a polygon mirror wheel with tilted mirrors to deflect its focused laser<br />

beam extremely quickly. As a result, it creates a light spot that moves quickly in several rows<br />

across the reading plane. Each light spot repeatedly moves along a straight line. It thereby<br />

appears to human eyes as one of several stationary scan lines.<br />

Reading angle (RA value)<br />

The reading angle from the reading window to the red scanning line of the scanning beam<br />

under which the middle of a bar code is detected. Recorded by the bar code scanner for<br />

each scan and used, e. g., for the separation of bar codes with identical data contents. For<br />

the decoding process, the active analysis area along the scanning line can be restricted application-<br />

specifically by presetting the minimum and maximum RA values.<br />

Reading diagnosis data<br />

<strong>Code</strong>-, object- or device-related data which the bar code scanner derives directly from the<br />

reading process. The data allows, among other things, an assessment of the reading quality<br />

and to draw conclusions on the reading process.<br />

Reading gate, reading interval<br />

Time window in which the bar code scanner switches on the scanning line and attempts to<br />

recognise valid bar codes from the read information. The reading gate can be shorter than<br />

the external reading pulse, depending on the output mode of the selected reading result.<br />

Reading pulse<br />

Triggering of the internal reading gate via a bar code scanner-external pulse is carried out<br />

by means of an external trigger source such as a photoelectric reflex switch or a command<br />

string via the data interface. With internal trigger source "automatic tick", the bar code scanner<br />

creates the reading pulse itself.<br />

Reading range (DOF)<br />

Depth of field at both sides of the lens focal point at the reading level. The size of the range<br />

depends on resolution and reading distance.<br />

Reading result<br />

Electronic display and output of the data contents of the scanned bar codes together with<br />

reading diagnosis data in a data output string at the defined output time.<br />

8011970/S345/2008-04-16 © SICK AG · Division Auto Ident · Germany · All rights reserved 115