Operating Instructions Chapter 11<br />

<strong>CLV63x</strong> <strong>Bar</strong> <strong>Code</strong> <strong>Scanner</strong><br />

Appendix<br />

Start/Stop operation<br />

In this reading operation mode, only one object per reading pulse is located in the reading<br />

area. Two external sensors or command strings control the beginning and end of the reading<br />

pulse for the bar code scanner (stand-alone device). The length of the reading area is<br />

determined in this case by the distance of both reading pulse sensors for the start (beginning<br />

of the reading area) and stop (end of the reading area). The minimum reading distance<br />

between two objects must always be greater than the length of the reading area.<br />

In the case of combined use with other bar code scanners in a master/slave combination<br />

(e.g. unidirectional double-side reading), the bar code scanner as a slave receives its pulse<br />

signals from another bar code scanner (master). The bar code scanners are networked via<br />

the CAN interface, the output of the master’s reading result via its RS- 232/RS-422/485<br />

interface and/or the Ethernet interface.<br />

Upload<br />

Transfer process of all parameter values from the connected bar code scanner’s working<br />

memory to a PC in the SOPAS-ET configuration software for display and modification. This<br />

is achieved when the device is connected and communication is successfully carried out after<br />

the scanning process for a confirmed request to synchronise the user interface and the<br />

bar code scanner. Where necessary, this can be triggered manually in the Kommunikation<br />

menu (UPLOAD ALL PARAMETERS FROM DEVICE Parameter values must be represented in the register<br />

tabs before the current parameter value set can be modified.<br />

User interface<br />

Windows-oriented input interfaces in the SOPAS-ET configuration software for operation<br />

and configuration of the bar code scanner.<br />

8011970/S345/2008-04-16 © SICK AG · Division Auto Ident · Germany · All rights reserved 117