Operating Instructions Chapter 10<br />

<strong>CLV63x</strong> <strong>Bar</strong> <strong>Code</strong> <strong>Scanner</strong><br />

10 Technical data<br />

Technical data<br />

10.1 Datenblatt <strong>Bar</strong>codescanner <strong>CLV63x</strong> (Linien-/<br />

Rasterscanner)<br />

Type <strong>CLV63x</strong> <strong>Bar</strong> <strong>Code</strong> <strong>Scanner</strong><br />

Focus Fixed focus<br />

Reading window Line / Raster scanner: With front/side reading window (with angle attachment: light entrance/exit<br />

under 105°)<br />

Laser diode (wavelength) Red light (λ = 655 nm)<br />

MTTR of the laser diode 20,000 h<br />

Device laser class Class 2 in accordance with IEC 60825-1 and EN 60825-1, see warning sign on device for date of<br />

publication<br />

Useable aperture angle max. 50° (front reading window and side reading window)<br />

Scan/decoder frequency 400 ... 1,200 Hz<br />

Resolution 0,15 ... 1.0 mm (5.9 ... 39.5 mil) (type-dependent)<br />

Raster height 15 mm (0.6 in) (8 lines) with 200 mm (7.9 in) reading distance (front reading window)<br />

<strong>Bar</strong> code print contrast (PCS) ≥ 60 %<br />

Ambient light compatibility 2,000 lx (on bar code)<br />

Number of bar codes per scan 1 ... 20 standard decoder; 1 ... 6 SMART decoder<br />

Number of bar codes per reading<br />

gate1) 1 ... 50 bar codes (auto-discriminating)<br />

<strong>Bar</strong> code types <strong>Code</strong> 39, <strong>Code</strong> 128, <strong>Code</strong> 93, Codabar, EAN, EAN 128, UPC, 2/5 Interleaved, Pharmacode<br />

<strong>Bar</strong> code lengths Max. 50 characters (max. 5,000 characters across all bar codes per reading gate, 500 characters<br />

with multiplexer function (CAN))<br />

Print ratio 2:1 ... 3:1<br />

Number of multireads 1 ... 99<br />

Memory card for parameters<br />

(cloning)<br />

Micro SD card (flash card) 512 MB, optional<br />

Optical indicators 6 LEDs: Ready, Result, Laser, Data, CAN, LNK TX and bargraph display<br />

Acoustic display Beeper, can be switched off, with function for result status display<br />

Control elements 2 buttons (selecting and starting/stopping functions)<br />

Reading pulsing Pulse sources for start: Switching inputs "Sensor 1" 2) and/or "Sensor 2"; command; Automatic<br />

Cycle; CAN<br />

Pulse sources for stop: Reading pulse source, "Sensor 1", "Sensor 2", command, timer, good read,<br />

condition<br />

"Host" data interface Serial: RS-232 or RS-422/485; Ethernet (port 2112),<br />

adjustable data format (serial) and data output format<br />

Data transfer rate 2,4 ... 115.2 kbd<br />

Protocols SICK standard (SOPAS-Cola-A)<br />

Physical configurations Stand-alone<br />

"Aux" data interface Serial: RS-232 (57.6 kbd; 8 data bits, no parity, 1 stop bit); Ethernet (port 2111); fixed data output<br />

format<br />

"Ethernet" data interface Only for Ethernet version: 10/100 MBit/s, TCP/IP, half/full duplex<br />

"CAN" data interface 20 kBit/s ... 1 MBit/s, SICK CAN-SENSOR network (Master, Slave, Multiplexer)<br />

Digital switching inputs Standard version: 2 ("Sensor 1", "Sensor 2"), 2 additional inputs via CMC600 in CDB620<br />

Ethernet version: 1 ("Sensor 1"), 2 additional inputs via CMC600 in CDB620, optodecoupled, Vin =<br />

max. 32 V, reverse polarity protected, can be wired with PNP output, configurable debouncing 0<br />

...10.000 ms<br />

8011970/S345/2008-04-16 © SICK AG · Division Auto Ident · Germany · All rights reserved 77