( ... C<strong>on</strong>tinued)<br />

8.<br />

9.<br />

10.<br />

11.<br />

12.<br />

13.<br />

14.<br />

15.<br />

16.<br />

Lighting energy<br />

savers (voltage<br />

c<strong>on</strong>troller)<br />

Efficient lamps<br />

(T5, CFL, métal<br />

halide, HPSV)<br />

Transparent<br />

roofing sheets to<br />

reduce lighting<br />

load<br />

<strong>Energy</strong>-efficient<br />

water pumps<br />

FRP blades for<br />

cooling tower<br />

fans<br />

Efficient spray<br />

nozzles in cooling<br />

towers<br />

Compressed<br />

air ON/OFF<br />

c<strong>on</strong>troller<br />

Compressed<br />

air generati<strong>on</strong><br />

pressure<br />

reducti<strong>on</strong><br />

Compressed<br />

air leakage<br />

reducti<strong>on</strong><br />

Applicable/<br />

Not Applicable<br />

Applicable/<br />

Not Applicable<br />

Applicable/<br />

Not Applicable<br />

Applicable/<br />

Not Applicable<br />

Applicable/<br />

Not Applicable<br />

Applicable/<br />

Not Applicable<br />

Applicable/<br />

Not Applicable<br />

Applicable/<br />

Not Applicable<br />

Applicable/<br />

Not Applicable<br />

- 125 -<br />

Annex<br />

(15–20% <strong>on</strong><br />

operating lighting<br />

kW)<br />

(30–50% of<br />

existing lighting<br />

kW)<br />

(Avoids at least<br />

25% of existing<br />

Shop Floor Day<br />

Lighting)<br />

(Improvement in<br />

existing efficiency<br />

up to 75%)<br />

(Being small<br />

fans reducti<strong>on</strong> of<br />

5-7% <strong>on</strong> existing<br />

fan kW drawl)<br />

(Improves spray<br />

in mist form<br />

and completely<br />

eliminates need<br />

for CT-ID fan)<br />

(3–5% Savings<br />

in overall<br />

existing kWh<br />

c<strong>on</strong>sumpti<strong>on</strong>)<br />

(8% reducti<strong>on</strong> in<br />

motor input kW<br />

for every 1 kg/<br />

cm2 reducti<strong>on</strong><br />

in discharge<br />

pressure)<br />

(Direct saving-<br />

Leakage based<br />

<strong>on</strong> Trial (or<br />

estimated) varies<br />

between<br />

10–40%)<br />

(C<strong>on</strong>tinued <strong>on</strong> next page)