1901.] THE LOCOMOTIVE. 133<br />

(186.)— A boiler exploded on Juiie 20th, on the farm of Joshua Strange, nine miles<br />

east of Marion, Ind. Ernest Strange was fatally injured, and John Sherron was badly<br />

hurt, though he will recover.<br />

(187.) — On June 20th the boiler of a big mogul freight engine on the Chicago &<br />

Alton railroad exploded at Blue Cut, some fifteen miles east of Kansas City, Mo. Engi-<br />

neer George Gerew was killed, and Fireman Willis Crowley was fatally injured.<br />

None of the passengers was injured. <strong>The</strong> tracks were torn up for a distance of 100<br />

feet.<br />

(188.) — On June 29th a boiler exploded in Simon Bartlett's sawmill, on George's<br />

Creek, ten miles from Louisa, Ky. Oscar Miller, who was running the mill, was badly<br />

scalded, and his two children, who were playing near the boiler, were scalded so<br />

badly that one of them died during the following night, and the other probably cannot<br />

live.<br />

Inspector's Report.<br />

April, 1901.<br />

During this month our inspectors made 10,570 inspection trips, visited 20,105<br />

boilers, inspected 8,756 both internally and externally, and subjected 959 to hydrostatic<br />

pressure. <strong>The</strong> whole number of defects reported reached 15,890, of which 1,063 were<br />

considered dangerous ; 144 boilers were regarded unsafe for further use. Our usual<br />

summary is given below :<br />

Nature of Defects.<br />

Cases of deposit of sediment,<br />

Cases of incrustation and scale,<br />

Cases of internal grooving, -<br />

...<br />

Cases of internal corrosion, - - - -<br />

Cases of external corrosion, -<br />

Broken and loose braces and stays, -<br />

-<br />

-.-'-•-•-<br />

Settings defective,<br />

Furnaces out of shape,<br />

-<br />

Fractured plates, -<br />

Burned plates, --.-""<br />

Blistered plates,<br />

Cases of defective riveting, •<br />

Defective heads,<br />

_---.--<br />

___-•-<br />

Serious leakage around<br />

....<br />

tube ends, -<br />

Serious leakage at seams, -<br />

Defective water-gauges,<br />

Defective blow-offs, - - - - -<br />

Cases of deficiency of water,<br />

Safety-valves overloaded,<br />

- - - -<br />

---..-<br />

...<br />

Safety-valves defective in construction,<br />

Pressure-gauges defective, - - - -<br />

Boilers without pressure-gauges, ''----<br />

..... Unclassified defects,<br />

Total, 15,890<br />

r hole Number.<br />

1,063