7 Programming with Q Parameters<br />
7.7 Measuring with the 3D Touch Probe During Program Run<br />
7-12<br />
The 3D touch probe can measure positions on a workpiece during program<br />
run.<br />
Applications:<br />
• Measuring differences in the height of cast surfaces<br />
• Checking tolerances during machining<br />
Enter G55 to activate the touch probe.<br />
The touch probe is automatically pre-positioned (with rapid traverse from<br />
MP6150) and probes the specified position (with feed rate from MP6120).<br />
The coordinate measured for the probe point is stored in a Q parameter.<br />
The <strong>TNC</strong> interrupts the probing process if the probe is not deflected within<br />
a certain range (range selected with MP6130).<br />
To program the use of a touch probe:<br />
G<br />
e.g. 5 ENT<br />
e.g.<br />
e.g.<br />
5<br />
e.g. Z<br />
5<br />
5<br />
0<br />
ENT<br />
PARAMETER NUMBER FOR RESULT ?<br />
PROBING AXIS/PROBING DIRECTION?<br />
e.g.<br />
e.g.<br />
X<br />
Y<br />
X<br />
+/<br />
END<br />
+/<br />
5<br />
Select the touch probe function.<br />
Y<br />
100<br />
–10<br />
Z<br />
L?<br />
α?<br />
α?<br />
Fig. 7.4: Workpiece dimensions to be<br />
measured<br />
Enter the number of the Q parameter to which the coordinate is to be<br />
assigned, for example Q5.<br />
Enter the probing axis for the coordinate, for example X.<br />
Select and confirm the probing direction.<br />
Enter all coordinates of the pre-positioning point values,<br />
for example X = 5 mm, Y = 0, Z = –5 mm.<br />
Conclude input.<br />
Resulting NC block: N150 G55 P01 05 P02 X- X+5 Y+0 Z-5 *<br />
Pre-position the touch probe manually such that it will not collide with the workpiece when it moves toward the<br />
programmed position.<br />
X<br />
100<br />
<strong>TNC</strong> <strong>360</strong>