Volume-II - GAIL
Volume-II - GAIL
Volume-II - GAIL
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
TABLE – 2<br />
S.No Properties Frequency (1)<br />
Applicable Requirement<br />
1 Bond Strength 5 Pipes Para 10.5<br />
2 Impact Strength 3 Pipes Para 10.6<br />
3 Indentation Hardness 5 Pipes Para 10.7<br />
4 Elongation at Failure 3 Pipes Para 5.3.3(iv) & 7.5.2(iv)<br />
5 Cathodic Disbondment 2 Pipes Para 5.3.3(viii) & 7.5.2(v) (2)<br />
6 Degree of Cure 2 Pipes Para 5.3.3(ix) & Para 10.9(i)<br />
7 Coating Resistivety 2 Pipes Para 5.3.3 (v) (3)<br />
8 Heat Ageing 2 Pipes Para 5.3.3 (vi) (3)<br />
9 Light Ageing 2 Pipes Para 5.3.3 (vii) (3)<br />
10 Adhesion 2 Pipes CSA Z 245.20 – 98, Table - 4<br />
1) Test frequency shall be as indicated in this table and the frequency indicated in the<br />
applicable paragraphs of the specific are not applicable.<br />
2) Two tests each on the selected pipes i.e 30 days and 48 hours test shall be carried out<br />
on each test pipe.<br />
3) Previously carried out tests in an independent laboratory of national / international<br />
recognition on PE top coat are also acceptable.<br />
<strong>GAIL</strong> (INDIA) LIMITED<br />
3 – LAYER POLYETHYLENE<br />
COATING OF LINEPIPES<br />
<strong>GAIL</strong>-TS-COATING-3LPE<br />
Page 35 of 35