ANP PROJECT QUARTERLY PROGRESS REPORT<br />

-.<br />

* *<br />

Fig. 11.4. Hot Leg of Inconel Loop Tested for 500 hr at 816OC with<br />

NaF-ZTF4-UF4 Prepared in 30-lb Batches. 250X.<br />

corrosion tests, <strong>the</strong>re appears to be<br />

some correlation (which did not exist<br />

in static tests) between <strong>the</strong> amount of<br />

<strong>the</strong> olive-drab phase and <strong>the</strong> extent of<br />

corrosion.<br />

Hydrofluorinated NaF-KF-LiF-UF4.<br />

One o<strong>the</strong>r series of tests points to<br />

poor production technique as <strong>the</strong> cause<br />

of <strong>the</strong> trouble discussed above. The<br />

attack found in Inconel loops in which<br />

NaF-ZrF,-UF, (46-50-4 mole %) was<br />

circulated had been only one half of<br />

that found with NaF-KF-LiF-UF, ( 10.9-<br />

43.5-44.5-1.1 mole %). One explanation<br />

for this has been <strong>the</strong> higher purity of<br />

<strong>the</strong> ZrF4-bearing fluoride. During<br />

product ion, <strong>the</strong> ZrF, - bear in g materia 1<br />

is purified with both hydrogen and<br />

hydrogen fluoride, whereas <strong>the</strong> NaF-KF-<br />

LiF-UF, is not, Two special batches<br />

of NaF-KF-LiF-UF4 were prepared by <strong>the</strong><br />

136<br />

t'<br />

group that makes <strong>the</strong> NaF-ZrF,-UF,, and<br />

<strong>the</strong> same techniques were used. Un-<br />

expectedly, <strong>the</strong> metal impurities in <strong>the</strong><br />

specially prepared batches were much<br />

higher than in <strong>the</strong> normal material.<br />

In <strong>the</strong> two special batches, <strong>the</strong> metal<br />

impurities were:<br />

MTCH 1 BATCH 2<br />

Chromium, ppm 2200 1280<br />

Iron, ppm 5600 7000<br />

Nickel, ppm 7 100 5300<br />

The presence of <strong>the</strong>se impurities has<br />

not yet been explained. Metallographic<br />

examination after a test with <strong>the</strong><br />

first batch revealed a maximum hot<br />

leg attack of 30 mils, with an average<br />

of 18 m i l s . This is <strong>the</strong> deepest<br />

attack yet found with any fluoride<br />

loop. A loop is now being run to