ANP PROJECT QUARTERLY PROGRESS REPORT<br />

CREEP UNDER IRRADIATION<br />

W. W. Davis J. C. Wilson<br />

J. c. Zukas<br />

Solid State Division<br />

Additional cantilever creep tests<br />

on Inconel with <strong>the</strong> standard ARE 2-hr,<br />

1100°F anneal were carried out a t<br />

1500°F in air atmospheres in <strong>the</strong><br />

graphite reactor and <strong>the</strong> LITR. As<br />

shown in Figs. 14.1 and 14.2, <strong>the</strong>re<br />

are only small differences between <strong>the</strong><br />

bench and in-reactor tests. The upward<br />

deflection after 400 hr in <strong>the</strong> curve<br />

for <strong>the</strong> 3000-psi test in <strong>the</strong> ORNL<br />

graphite reactor is probably due to<br />

faulty operation of <strong>the</strong> temperature<br />

controller. The results are to be<br />

checked by postirradiation measure-<br />

ments of <strong>the</strong> creep deflections 011 a<br />

remotely con tro 11 ed pro fi lome ter.<br />

188<br />

-BENCH TEST<br />

Postirradiation measurements were<br />

made on specimens annealed at 1650°F<br />

and irradiated in <strong>the</strong> graphite reactor<br />

at 1500°F. Their creep curves were<br />

shown in a previous report(') as curve<br />

A, 1500 psi, and curve C, 2000 psi.<br />

The profilometer measurements indicated<br />

that. <strong>the</strong> large extensions which were<br />

measured were in error and that <strong>the</strong><br />

actual extensions were not much<br />

greater than those occurring in <strong>the</strong><br />

bench tests. Several tests reported<br />

last quarter as being in progress were<br />

negated by faulty microformers.<br />

The design for <strong>the</strong> bellows-loaded<br />

tensile creep test, in <strong>the</strong> MTR is near-<br />

ing completion, and most, of <strong>the</strong> com-<br />

ponents have been fabricated and<br />

partly assembled for test.<br />

(').I. C. Wilson. J. C. Zukas, and W. W. Davis,<br />

ANP Quar. Frog. Rep. June 10, 1952, ORNL-1294.<br />

p. 164.<br />

SSD-A-499<br />

DWG. i 7037A<br />

0 200 400 600<br />

TIME (hr)<br />

Fig. 14.1. Cantilever Creep Tests on Ineonel in Air at 1500"~ and is00 psi.