8.5.2.14 Wherever time and facilities are available the passenger locomotives should<br />

immediately be washed.<br />

8.6 MONTHLY INSPECTION (IA)<br />

8.6.1 Tests<br />

The supervisor <strong>of</strong> E2 section should carry out tests listed below before and after the<br />

inspection .<br />

8.6.1.1 Preliminary tests with 25 kV supply ON –<br />

a) Measure and record battery (BA) voltage.<br />

b) Measure and record battery charger voltage.<br />

kg/ cm².<br />

c) Check time taken to build up compressed air pressure from 1 kg/cm² to 8-9<br />

d) Check blowing out <strong>of</strong> safety valve.<br />

e) Check vacuum obtained with driver brake control valve MPF or A9.<br />

f) After building up vacuum, check for vacuum leakage for 5 mins.<br />

g) Check vacuum drop required for brakes to apply.<br />

h) Note pressure gauge reading when brakes are applied.<br />

i) Check working <strong>of</strong> braking electro-valve VEF.<br />

j) Check working <strong>of</strong> blowers under 'direct' and 'automatic' starting conditions.<br />

k) Note and record air leakages for one minute in main reservoirs and brake<br />

cylinders.<br />

l) Test headlights.<br />

m) Test working <strong>of</strong> cab heaters and fans.<br />

8.6.1.2 Preliminary tests with 25 kV supply OFF -<br />

a) Measure and record time required for raising and lowering both the pantographs.<br />

b) Measure and record time taken for various time delay relays.<br />

c) Test functioning <strong>of</strong> auxiliary circuit earth fault relay (QOA) by creating an earth<br />

fault.<br />

d) Test functioning <strong>of</strong> power circuit earth fault (QOP) by creating an earth fault,<br />

e) Check functioning <strong>of</strong> all lights.<br />

8.6.1.3 Tests under high tension before and after inspection successively from cab 2 and