Traction Rolling Stock - Indian Railways Institute of Electrical ...
Traction Rolling Stock - Indian Railways Institute of Electrical ...
Traction Rolling Stock - Indian Railways Institute of Electrical ...
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
drum MP.<br />
5.8 AUXILIARY CONTROL CIRCUIT (Ref.fig. 5.5.2 & fig. 5.8.1)<br />
5.8.1 GENERAL<br />
The control circuits <strong>of</strong> the auxiliary motors are connected to 110 V dc supply from the<br />
battery circuit and are protected by fuse CCA. The auxiliary motors can be started only if the main<br />
circuit breaker DJ is closed. As soon as the auxiliary contacts <strong>of</strong> the main circuit breaker DJ and<br />
relay QCVAR have picked up, Cl18 contactor is de-energized and auxiliary interlock <strong>of</strong> C118<br />
closes after delay <strong>of</strong> 5 secs, and Q100 relay gets energized. Auxiliary interlock <strong>of</strong> Cl18 contactor is<br />
having adjustable mechanical time delay arrangement which closes with a delay <strong>of</strong> 5 secs, after<br />
opening <strong>of</strong> contactor Cl18.<br />
With the help <strong>of</strong> switches HCP, HVRH, HVMT1 and HVMT the contactors <strong>of</strong> the<br />
individual motor can be closed and opened.<br />
The opening positions <strong>of</strong> the switches are as follows:<br />
Position 0 – Auxiliary motors and functional relay disconnected.<br />
Position 1 – Auxiliary motor & functional relay in service.<br />
Position 2 – Auxiliary motor disconnected, functional relay in service.<br />
Position 3 – Auxiliary motor in service, functional relay disconnected.<br />
The contactors <strong>of</strong> the auxiliary motors are operated by the switches on BL key boxes in<br />
cab1&2. With multiple unit operation the auxiliary motors <strong>of</strong> the trailing locomotive are controlled<br />
from the leading locomotive. The contactor <strong>of</strong> the auxiliary motors in the trailing locomotive are<br />
switched on only if the respective main circuit breakers (DJ) are closed and Arno <strong>of</strong> that<br />
locomotive has started up. On the trailing locomotives the switched BLCP, BLCPD, BLVMT and<br />
BLPV are kept open. The battery switch HBA must be closed and all fuses inserted at their proper<br />
places.<br />
5.8.1 STRUCTURE OF MAIN COMPRESSOR<br />
After closing the switch BL1CP or BL2CP, the coils <strong>of</strong> contactor<br />
C101,C102, C103 energize, provided the relay Q100 has picked up and HCP is on<br />
''position 123".<br />
On closing <strong>of</strong> the contactor, the motors MCP 1-3 get the 3-phase 380 V ± 22.5% supply<br />
from the Arno. As soon as the pressure in the main compressed air line rises to 10 kg/cm²<br />
the pressure switch contact RGCP closes, disconnecting compressor contactor and connecting<br />
the compressor to through the unloader valve. The compressor is reconnected to supply when the<br />
pressure has dropped to below 8.5 kg/cm².