) Check capacitor <strong>of</strong> headlight stabilizer,<br />
c) Check transformer and tap changer oil for di-electric strength and acidity.<br />
Recondition/ replace, if necessary.<br />
d) Check the switch angle <strong>of</strong> SMGR.<br />
e) Overhaul SMGR.<br />
f) Lubricate all electro-pneumatic contactors.<br />
g) Check Q factor <strong>of</strong> electro-pneumatic contactors.<br />
h) Inspect dynamic braking resistor for damage. Overhaul and record resistance.<br />
Section E3<br />
Carry out the following:<br />
a) Lubricate Arno bearings, measure and record insulation resistance values.<br />
b) Overhaul brush holder insulators.<br />
c) Overhaul auxiliary machines.<br />
Section E4<br />
a) Overhaul and calibrate main power circuit overload relay (QLM), silicon rectifier<br />
overload relay (QRSI), electric braking overload relay (QF), braking excitation<br />
overload relay (QE), power circuit earth fault relay (QOP), auxiliary circuit earth<br />
fault relay (QOA) and No-volt relay (Q30).<br />
b) Overhaul and test Q118, Q44, QTD and Q 48.<br />
c) Overhaul and test SMGR relays (Q51, Q52), QD and Q20.<br />
d) Overhaul speedometer.<br />
8.10 INTERMEDIATE OVERHAUL (IOH)<br />
8.10.1. IOH <strong>of</strong> locos may be done at the homing shed itself or at a workshop nominated for the<br />
purpose.<br />
8.10.2. During IOH, in addition to a thorough inspection <strong>of</strong> all mechanical and electrical items as<br />
detailed under IA, IB, IC and AOH, squaring <strong>of</strong> bogies should be done and traction motors,<br />
rectifiers, auxiliary machines, blowers, tap changer, pantograph etc. should be taken <strong>of</strong>f the loco<br />
and overhauled. Transformer oil should be filtered and replaced if acidity is beyond the permissible<br />
limits. All wheels should be re-pr<strong>of</strong>iled. Insulation resistance <strong>of</strong> all HT and LT circuits should, be<br />
measured and recorded. Approved modifications, which can be executed in the shed, should be<br />
carried out.