The voltmeter UA-1, UA-2 are fitted in the control desks and have double scale on which<br />

the auxiliary voltage and the catenary voltage can be read.<br />

5.4.4 Voltage stabilizer for headlight (RTPR)<br />

The circuit is protected by fuse CCRTPR. This is meant for maintaining constant voltage<br />

for the headlights <strong>of</strong> the locomotive to ensure that these provide a uniform level <strong>of</strong> illumination and<br />

also to protect the lamps from fusing. It also feeds 24 V supply to the measuring instruments<br />

through switch BL1LF and BL2LF. This is also provided with a 16 V tap for dimming the headlight.<br />

5.4.5 Selsyn Transformer (TFS)<br />

The transformer supplies 115 V AC supply to the system which transmit the position<br />

<strong>of</strong> the tap changer GR to the control desk for indication after stepping down 230 V AC<br />

supply.<br />

5.4.6 Static Battery Charger CHBA<br />

The static battery charger is fed from the supply <strong>of</strong> Arno converter. The unit comprises<br />

<strong>of</strong> a stepdown transformer, magnetic amplifier and rectification unit. The charger is able to give an<br />

output voltage <strong>of</strong> 110V DC and a load 20 Amps.<br />

5.5 TRACTION CONTROL CIRCUIT<br />

5.5.1 Compressed air for operation <strong>of</strong> pantographs and high voltage circuit breaker<br />

When the pressure in the auxiliary air reservoir and in the compressed air lines to the<br />

pantographs and the high voltage circuit breaker exceeds 5.5kg/cm² the pantographs may be<br />

raised and the high voltage circuit breaker can be closed.<br />

If the pressure lies below this value or drops while the pantographs are being raised it will<br />

be necessary to start up the auxiliary compressor set. This is done by closing the switch ZCPA.<br />

The pressure can be observed on the pressure gauge mounted above auxiliary<br />

reservoir for pantograph in AC1 cubicle in Cab1<br />

5.5.2 Operation <strong>of</strong> pantographs (Ref. fig. 5.5.2)<br />

The pantographs are operated by the pantograph selector switch ZPT1 or ZPT2 in the<br />

drivers desk. For this purpose the driver requires the operating key <strong>of</strong> the pantograph selector<br />

switch.<br />

The same operating key is required for unlocking the interlocking box BV and can be<br />

removed from this box only when the key for the high voltage compartment doors have been<br />

inserted and the ro<strong>of</strong> earthing switch HOM has been opened or brought to normal working<br />

position.<br />

Further, the operating key <strong>of</strong> the pantograph selector switch can be removed or fitted<br />

only in the zero position.<br />

The pantograph selector switches have the following positions.<br />

Position 0<br />

– The two solenoid valves VEPT1 & VEPT2 are switched <strong>of</strong>f the