f) Inspect all resistance, including R 118 and braking resistances.<br />

g) Check all terminal boards.<br />

h) Test the manual control <strong>of</strong> tap changer servo-motor (SMGR), lubricate the level<br />

bars.<br />

i) Check the insulation values <strong>of</strong> transformer windings to earth.<br />

j) Check the springs <strong>of</strong> reverser and CTF and replace if necessary, verify the<br />

pressure on main contacts, clean the servo motor, check the operation <strong>of</strong> main<br />

and auxiliary contacts, check the rubber buckets.<br />

k) Lubricate contacts and the articulation points <strong>of</strong> Ll, L2, C 145 and shunting<br />

contactors and check rubber buckets.<br />

l) Inspect SJ and SL for any abnormality and clean.<br />

m) Inspect braking electro valves, Pantograph electro valves and sanding electro<br />

valves VEF, VEPT, VESA and VER.<br />

Section E3<br />

In addition to items under IA and IB<br />

a) Measure and record the insulation resistance <strong>of</strong> traction motor winding.<br />

b) Check visually for top circulating ring <strong>of</strong> rotor and its top position <strong>of</strong> rotor bar<br />

cracks in Arno and lubricate bearings.<br />

c) Check and clean the commutator and brush box auxiliary compressor motor.<br />

Section E4<br />

Carry out the following :<br />

a) Remove main contacts check wear <strong>of</strong> fixed and moving contacts. Replace if<br />

necessary.<br />

b) Check and adjust the gaps <strong>of</strong> lighting arresters.<br />

c) Check and clean the contacts <strong>of</strong> high tension overload relay (QLM), Smoothing<br />

rectifier circuit overload relay (QRSI), electric braking relay (QF), braking exciter<br />

overload relay (QE), auxiliary circuit earth fault relay (QOA), no voltage relay<br />

(Q30). Check proper alignment and bedding <strong>of</strong> contacts.<br />

d) Check collector comb, dropping resistance and multi-core cable. Replace carbon<br />

brush if necessary,<br />

e) Clean and check operation <strong>of</strong> tap changer servo-motor (SMGR) relays and<br />

slipping device differential relay (QD), traction motor over voltage relay (Q20).<br />

8.9. ANNUAL OVERHAUL (AOH)<br />

These are in addition to the items listed under IA, IB and IC.