Traction Rolling Stock - Indian Railways Institute of Electrical ...
Traction Rolling Stock - Indian Railways Institute of Electrical ...
Traction Rolling Stock - Indian Railways Institute of Electrical ...
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
f) Inspect all resistance, including R 118 and braking resistances.<br />
g) Check all terminal boards.<br />
h) Test the manual control <strong>of</strong> tap changer servo-motor (SMGR), lubricate the level<br />
bars.<br />
i) Check the insulation values <strong>of</strong> transformer windings to earth.<br />
j) Check the springs <strong>of</strong> reverser and CTF and replace if necessary, verify the<br />
pressure on main contacts, clean the servo motor, check the operation <strong>of</strong> main<br />
and auxiliary contacts, check the rubber buckets.<br />
k) Lubricate contacts and the articulation points <strong>of</strong> Ll, L2, C 145 and shunting<br />
contactors and check rubber buckets.<br />
l) Inspect SJ and SL for any abnormality and clean.<br />
m) Inspect braking electro valves, Pantograph electro valves and sanding electro<br />
valves VEF, VEPT, VESA and VER.<br />
Section E3<br />
In addition to items under IA and IB<br />
a) Measure and record the insulation resistance <strong>of</strong> traction motor winding.<br />
b) Check visually for top circulating ring <strong>of</strong> rotor and its top position <strong>of</strong> rotor bar<br />
cracks in Arno and lubricate bearings.<br />
c) Check and clean the commutator and brush box auxiliary compressor motor.<br />
Section E4<br />
Carry out the following :<br />
a) Remove main contacts check wear <strong>of</strong> fixed and moving contacts. Replace if<br />
necessary.<br />
b) Check and adjust the gaps <strong>of</strong> lighting arresters.<br />
c) Check and clean the contacts <strong>of</strong> high tension overload relay (QLM), Smoothing<br />
rectifier circuit overload relay (QRSI), electric braking relay (QF), braking exciter<br />
overload relay (QE), auxiliary circuit earth fault relay (QOA), no voltage relay<br />
(Q30). Check proper alignment and bedding <strong>of</strong> contacts.<br />
d) Check collector comb, dropping resistance and multi-core cable. Replace carbon<br />
brush if necessary,<br />
e) Clean and check operation <strong>of</strong> tap changer servo-motor (SMGR) relays and<br />
slipping device differential relay (QD), traction motor over voltage relay (Q20).<br />
8.9. ANNUAL OVERHAUL (AOH)<br />
These are in addition to the items listed under IA, IB and IC.