Np = 288 turns<br />
The beginning <strong>of</strong> the primary windings is led to the terminal A34 and is<br />
connected through the tap changer with the tapings A0 to A32 <strong>of</strong> the regulating<br />
transformer. The end <strong>of</strong> the winding is permanently connected to A0 internally<br />
Conductor cross Sectional area = 4 7 = 28 sq. mm - Auto winding<br />
3.8 5.5 sq. mm.- Primary winding<br />
The secondary windings (motor winding) are composed <strong>of</strong> two branches.<br />
a3..... a4 and<br />
a5..... a6<br />
Each branch has two sections connected in series, each having<br />
Ns = 12<br />
on both legs II and III<br />
Conductor cross area = 3.8 5.5 mm 2 (Primary and Secondary winding)<br />
1.2.2 BRIEF DATA OF POWER TRANSFORMER<br />
Type : HETT 3900<br />
Supplier : NGEF, CROMPTON GREAVES,BHEL