) Notch to notch relay Q52 must not be energized<br />

c) The valve ZSMGR must be at normal position.<br />

5.7.2.2 In case <strong>of</strong> auto regression <strong>of</strong> the tap changer GR the relay Q50 is de-energized. The<br />

'down' valve SMGR-VE2 is energized directly by passing BL and MP interlocks.<br />

5.7.2.3 Auto regression also takes place in the event <strong>of</strong> wheel slipping, the action takes place<br />

via line 700 and the closed contact <strong>of</strong> relay Q48. Relay Q48, is energized in the event <strong>of</strong> wheel<br />

slipping through relay QD. In such case slip protection relay Q51 is energized temporarily and<br />

gives supply to down valve SMGR-VE2 till the relay Q48 drops through relay QD after the arrest <strong>of</strong><br />

wheel slip.<br />

5.7.2.4 A down movement <strong>of</strong> the tap changer is interrupted automatically on reaching position<br />

“0” by interruption <strong>of</strong> the feed supply.<br />

5.7.2.5 The relay Q46 supervises the continued running <strong>of</strong> the air motor during regression with<br />

MP on position “0” and thus the return <strong>of</strong> the tap changer to zero.<br />

The following conditions must be satisfied for proper functioning <strong>of</strong> the relays<br />

a) The running braking drum MP must be at position "0"<br />

b) The tap changer must be on position other than zero<br />

c) The handle <strong>of</strong> the valve ZSMGR on the pneumatic control panel must be at the<br />

normal operating position.<br />

Should an air motor stop running with the tap changer away from the zero position and<br />

MP on position “0”, the relay Q46 remains energized and causes the relay Ql18 drop out and open<br />

DJ after 5 seconds,<br />

Any down or up movement <strong>of</strong> the tap changer can be stopped at any time by returning<br />

the master controller to position "N". The tap changer then remains at whatever position has been<br />

reached.<br />

5.7.3 CONTROL BY MASTER CONTROLLER – IMPULSE (+) OR (-)<br />

(Ref. fig. 5.7.2)<br />

The switch positions (+) or (-) are intended for notch by notch up or down movement <strong>of</strong><br />

the tap changer both for running and for braking operation.<br />

The switching sequences and inter relationship correspond to those described under<br />

5.7.2. In addition, the notch to notch relay Q52 goes into action, the feed lines 079 is energized at<br />

position (+) or (-).<br />

At all positions for up or down movement either the up or the down valve is energized.<br />

This energizing will be interrupted by contacts <strong>of</strong> the relay Q52 as soon as the air motor starts<br />

running. The relay Q52, is energized between notches via the contacts 7-8 ASMGR, this state<br />

being maintained via the self holding contacts in the line 079-087. The self holding circuit <strong>of</strong> Q52 is<br />

not cancelled until the master controller handle has been returned to position "N". This<br />

arrangement ensures that the tap changer always moves by only one notch at a time. The<br />

completion <strong>of</strong> the notch to notch movement is assured by the pneumatic control system.