Peak short ckt. current with smoothing … 27000 A<br />

reactor in circuit connection … Graetz bridge<br />

(a)<br />

Particulars <strong>of</strong> components in rectifier assly. <strong>of</strong> M/s AEG/NGEF Ltd.<br />

No. <strong>of</strong> cells in parallel per arm … 4 Nos.<br />

No. <strong>of</strong> cells in series … 3 Nos.<br />

Cell Type … D400/2000<br />

Cooling … 2 blowers - 3200m³ /hr<br />

Main fuse, 64 nos./loco … Type NG3, 500A, 800V<br />

Signal fuse 32 nos./loco … Type N300, 1200V<br />

Cell damping network :<br />

Resistor … Type RW 12/76 FST<br />

47 kohm ± 5%<br />

DC damping network :<br />

Resistor … Type GBs 30/B3-8 ohms with<br />

fixed central tap 4+4 ohms.<br />

Capacitor … 22uF 380 V<br />

DMVSI … 2 Nos./Loco-siemen's<br />

make (Imported)<br />

Micro Switch … Y-6, E-NR 910-161.500. 02.<br />

(b)<br />

Particulars <strong>of</strong> components in Rectifier Assly. <strong>of</strong> M/s Ruttonsha.<br />

Diode … Type 321 UMR 200 with<br />

heat sink type HK 1539A<br />

321 UFR 200 with Heat<br />

sink type WK1539/Bore<br />

No. <strong>of</strong> cells in series … 3<br />

No. <strong>of</strong> cells in parallel … 2<br />

Cooling … 2 blowers-3200m² /hr.<br />

Main fuse … 64 nos.<br />

Type NG3 500A 800 V.<br />

Single fuse … 32 nos<br />

Type IR 1 : 1000, 700.rms.<br />

Cell damping network<br />

Series resistor … 10 ohms, 25 W.<br />

Hole storage capacitor … 2.5mfd, 1200V.<br />

Potential divider resistor … 25 Kohms, 25W.<br />

DC damping network