The main lighting circuits are fed from the regulated 110V supply across wires D8 and '<br />

GD. They are protected by the main lights supply fuse MLSF and are controlled by the second<br />

pole <strong>of</strong> the double -pole lighting contactor (see under Emergency Lights). This is latched contactor,<br />

under the control <strong>of</strong> the guard. Only momentary pulses from the LIGHTS ON and LIGHTS OFF<br />

buttons in the driving trailer cab are required to operate it. The circuit divides into two halves each<br />

branch supplying the half the lights throughout the train, and each being protected by fuse, MLF1<br />

& MLF2.