These machines are capacitor start and run single phase induction motors and are<br />

protected by individual fuses MCB on the live side <strong>of</strong> each machine. Also connected directly<br />

across the 266V supply is a no-volt relay NVR. This is a d.c. relay fed by a bridge connected<br />

rectifier, and is used to detect when the transformer is 'ive. On failure <strong>of</strong> line voltage, NVR drops<br />

out and disconnects the traction circuit by means <strong>of</strong> its contacts NVR1 and NVR2 in the control<br />

circuits. The NVR circuit is protected by a miniature circuit breaker.<br />

The aux.2 winding is protected against a fault in the wiring <strong>of</strong> the 266V a.c. circuit by two<br />

main fuses API and AF2,situtated within the transformer connection chamber.<br />

10.5.2 141V a.c. circuit (Ref. fig. 10.5.2)<br />

This circuit is fed from a second tertiary winding aux. 1 (141V ac) and is protected by<br />

two fuses AF3 and AF4,located inside the transformer connection chamber.<br />

A rectifier-fed relay LTR is provided to prove that fuses AF3 and AF4 are intact and that<br />

the voltage <strong>of</strong> aux. 1 winding is applied to the auxiliary supply rectifier (ASR). The circuit <strong>of</strong> LTR is<br />

protected by a miniature circuit breaker.<br />

A surge suppression capacitor with a series resistor is provided across the input to ASR.<br />

10.5.3 Main-compressor motor (Ref fig 10.5.2)<br />

The main compressor motor is protected by fuse AF10 and a permanent series resistor,<br />

and its contactor CC1 which is in turn controlled by a trip and set relay CR, through the<br />

compressor governor.<br />

Compressor synchronising is achieved through train line wire 13.<br />

When the COMPRESSOR SET button in any driving cab is pressed, train line 12 is<br />

energised, setting all the compressor relays in the train and the contact CR/1 completes the<br />

respective compressor contactor coil (CCl) circuit. This closes the compressor contactor.<br />

To switch <strong>of</strong>f the compressor motors the COMPRESSOR TRIP button in the cab is<br />

pressed this energises train line 42, tripping the compressor relays and the compressor<br />

contactors.<br />

A sealed switch GS3 is provided to short circuit the main-compressor governor if it sticks<br />

in the open position. Two miniature circuit breakers protect the circuit in such a way that faults in<br />

various parts <strong>of</strong> the circuit do not disable the train. The blocking rectifier between wire 1445 and<br />

1446 is provided to prevent the batteries in two units operating in multiple from being connected in<br />

parallel.<br />

10.5.3 Smoothing reactor<br />

This is provided to smoothen the ripple on the output <strong>of</strong> the auxiliary-supply rectifier.<br />

This voltage is then fed to the fans.<br />

10.5.4 Ventilating fans