BA + 0x408h (1032): DAC3 Update Register (Write)<br />

16-bit Operation. A write to this register will load the value into DAC3 and automatically update the DAC when<br />

bit 8 of BA + 0x400h is set to 0.<br />

D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0<br />

Bit 16 Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1<br />

BA + 0x40Ah (1034): DAC4 Update Register (Write)<br />

16-bit Operation. A write to this register will load the value into DAC4 and automatically update the DAC when<br />

bit 8 of BA + 0x400h is set to 0.<br />

D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0<br />

Bit 16 Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1<br />

BA + 0x410h (1040): Analog Threshold Detector Setup (Read/Write)<br />

16-bit Operation. The Threshold Trigger Level value (bits 7 to 0) can be anything between 0x00h and 0xFFh.<br />

Refer to Analog Trigger on page 80 for further information and corresponding voltage values for each<br />

hexadecimal number.<br />

D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0<br />

Trigger On<br />

0 = A/D value < threshold<br />

1 = A/D value > threshold<br />

Use Threshold<br />

0 = Do not use analog trigger<br />

1 = use analog trigger<br />

Read: Bit 15 = reserved<br />

Write: Bit 15 = 0<br />

Analog Input<br />

Channel Select<br />

00000 = channel 1<br />

00001 = channel 2<br />

00010 = channel 3<br />

00011 = channel 4<br />

00100 = channel 5<br />

00101 = channel 6<br />

00110 = channel 7<br />

00111 = channel 8<br />

01000 = channel 9<br />

01001 = channel 10<br />

01010 = channel 11<br />

01011 = channel 12<br />

01100 = channel 13<br />

01101 = channel 14<br />

01110 = channel 15<br />

01111 = channel 16<br />

•<br />

•<br />

•<br />

11111 = channel 32<br />

Threshold Trigger Level<br />

BDM-610010034 Rev C Chapter 4: I/O Mapping 53