Base Address Jumper (Factory Setting: 300 hex, 768 decimal)<br />

One of the most common causes of failure when you are first trying your module is address contention. Some of<br />

your computer’s I/O space is already occupied by internal I/O and other peripherals. When the module attempts<br />

to use I/O address locations already used by another device, contention results and the board does not work.<br />

To avoid this problem, the DM6425HR has an easily accessible jumper (J7) that lets you select any one of 16<br />

starting addresses in the computer’s I/O. If the factory setting of 300 hex (768 decimal) is unsuitable for your<br />

system, you can select a different base address simply by setting the jumper to any one of the values listed in<br />

Table 4. The table shows the jumper settings and their corresponding hexadecimal and decimal (in parentheses)<br />

values. Be sure to verify the order of the numbers on the jumper (1 through 4) before setting them. When you<br />

set the base address for your module, record the value on the back cover of this manual. Figure 9 shows the BASE<br />

ADDR jumper (J7) set for a base address of 300 hex (768 decimal).<br />

Note In Table 4, 0 = closed or down, corresponding to a logical “0”, and 1 = open or up, corresponding to<br />

a logical “1”. The factory default base address is shaded.<br />

Table 4<br />

DM6425HR dataModule Base Address Jumper Settings<br />

Base Address<br />

Hex/(Decimal)<br />

Jumper Settings<br />

4 3 2 1<br />

Base Address<br />

Hex/(Decimal)<br />

200/(512) 0 0 0 0 300/(768) 1 0 0 0<br />

220/(544) 0 0 0 1 320/(800) 1 0 0 1<br />

240/(576) 0 0 1 0 340/(832) 1 0 1 0<br />

260/(608) 0 0 1 1 360/(864) 1 0 1 1<br />

280/(640) 0 1 0 0 380/(896) 1 1 0 0<br />

2A0/(672) 0 1 0 1 3A0/(928) 1 1 0 1<br />

2C0/(704) 0 1 1 0 3C0/(960) 1 1 1 0<br />

2E0/(736) 0 1 1 1 3E0/(922) 1 1 1 1<br />

Jumper Settings<br />

4 3 2 1<br />

1<br />

2<br />

3<br />

4<br />

Figure 9 Base Address Jumper (J7)<br />

(shown in the factory default setting)<br />

BDM-610010034 Rev C Chapter 2: DM6425HR Module Settings 17