Annexure 'A' to Directors’ <strong>Report</strong><br />

PARTICULARS REQUIRED UNDER THE COMPANIES (DISCLOSURE OF PARTICULARS IN THE REPORT OF THE BOARD OF<br />

DIRECTORS) RULES, 1988.<br />

A. CONSERVATION OF ENERGY<br />

a) ENERGY CONSERVATION MEASURES TAKEN :<br />

i) Conversion of boiler no. 5 & 6 stroker coal fired boilers at Power House No. 3 into by-product<br />

gas fired boilers.<br />

ii) Commissioning of 2nd LD Gas holder to enhance LD Gas Recovery.<br />

iii) Phasing out of old and inefficient coal fired boilers at Boiler House No. 1<br />

iv) Upgradation of E blast furnace to high top pressure operation thereby reducing blast furnace fuel rate.<br />

b) ADDITIONAL INVESTMENTS AND PROPOSAL FOR REDUCTION OF CONSUMPTION OF ENERGY :<br />

i) Modification of two numbers of stroker fired boilers into by-product gas fired boilers at Power House<br />

No. 3 to reduce boiler coal consumption.<br />

ii) Installation of Top recovery turbine at ‘G’ & ‘H’ Blast Furnace.<br />

iii) Recovery of sensible heat of coke by installation of Coke Dry Quenching system in Batteries 5, 6 & 7<br />

at Coke Plant.<br />

iv) Phasing out of inefficient boilers and replacement of old and inefficient Blast Furnace blowers.<br />

v) Use of lean by-product fuel at re-heating furnaces by adopting regenerative burner technology.<br />

c) IMPACT OF THE ABOVE MEASURES :<br />

Energy Conservation measures during <strong>2006</strong>-<strong>2007</strong> has resulted in achieving:<br />

i) Lowest ever Plant Specific Energy Consumption of 6.717 Gcal/tcs.<br />

ii) Lowest ever boiler coal consumption of 66.77 kg/tss.<br />

iii) Lowest ever Plant Power Rate of 398.52 kwh/tss.<br />

iv) Higher LD Gas Recovery of 55.51 NM 3 /tcs.<br />

v) Lower specific oxygen consumption of 54.55 Nm 3 /tcs at steel melting shops.<br />

vi) Reduction in process steam condensate loss of 23.12 tonnes per hour.<br />

vii) Higher combine boiler efficiency of 81.48%.<br />