Detectable Problems 197<br />

Figure 12-8. Dual spool gas turbine estimated parameter changes<br />

with low compressor efficiency changes.<br />

discharge pressure (P 3<br />

), fuel flow, exhaust gas temperature (T 7<br />

), and<br />

both high (T 4<br />

) & low (T 3<br />

) compressor discharge temperatures (Figure<br />

12-9).<br />

The equipment manufacturer normally specifies cleaning agents.<br />

Typically, carbo-blast and water-wash are specified, with water-wash<br />

being the first method recommended. Care should be taken in cleaning<br />

compressors that are salt-laden, since the cleaning process will