382 Gas Turbine Handbook: Principles and Practices<br />

Repeating the above calculations yields a compressor discharge temperature<br />

of 383°F. At 200 psia & 380°F the water will be at the Liquid-Vapor<br />

Line (this can be confirmed on the Mollier Chart).<br />

Too much liquid water injected into the compressor will result in<br />

changing the airfoil configuration as water accumulates leading to<br />

compressor surge. Too much liquid water in the combustor will result<br />

in flame out. The amount of water resulting in either surge or flame<br />

out must be defined for each compressor model.