<strong>Canadian</strong> <strong>Quality</strong> <strong>Milk</strong><br />
Table 13: Recommended <strong>Milk</strong>ing Equipment Sanitation Procedures.<br />
CYCLE PURPOSE TEMP. RANGE BEST MANAGEMENT PRACTICES<br />
1 ST ⎯<br />
Pre-rinse<br />
milkline<br />
• Removes 90 to<br />
95% of milk solids<br />
• Warms up milkline<br />
• Lukewarm water,<br />
35°C to 60°C<br />
(95°F to 140°F)<br />
at the start of the<br />
cycle and<br />
minimum 35ºC<br />
(95°F) at the<br />
completion of the<br />
cycle<br />
Do not re-circulate water;<br />
otherwise, a milk film may be redeposited<br />
on system.<br />
Ensure water is not too hot;<br />
otherwise, protein will be baked<br />
onto milk contact surfaces.<br />
Reduce the amount of milk in<br />
waste disposal systems (some<br />
farmers save pre-rinse water<br />
and milk, and feed it to calves).<br />
Use amount of detergent<br />
according to the volume of water<br />
used and water quality (e.g.<br />
hardness, iron content).<br />
Follow manufacturer’s<br />
recommendations as written on<br />
milk house cleaning chart.<br />
The solution circulating during<br />
wash cycle should have a pH<br />
between 11.0 and 12.0, total<br />
alkalinity of 400 to 800 ppm,<br />
active alkalinity of 225 to 350<br />
ppm and chlorine content<br />
between 80 and 120ppm.<br />
Ensure wash cycle lasts 5 to 10<br />
minutes.<br />
Ensure a minimum of 20<br />
slugs/wash.<br />
Ensure acid rinse pH is less<br />
than 3.5.<br />
Add acid to acid rinse cycle after<br />
each milking.<br />
Never mix an acid detergent<br />
with a chlorine-based product ⎯<br />
mixing could produce an<br />
extremely toxic lethal gas.<br />
Ensure acid rinse cycle lasts<br />
between 3 to 4 minutes.<br />
2 nd ⎯<br />
Washing the<br />
milkline with<br />
chlorinated<br />
alkaline<br />
detergent<br />
• Removes fat and<br />
protein through<br />
addition of<br />
chlorinated alkaline<br />
detergent<br />
• Minimum start<br />
temperature of<br />
71 0 C (160 0 F)<br />
• Warmer than<br />
43°C (110 0 F) at<br />
end of cycle so<br />
that fat cannot<br />
redeposit on milk<br />
contact surfaces<br />
3 rd ⎯<br />
Rinsing the<br />
milkline with<br />
acid rinse<br />
• Neutralises<br />
detergent residues<br />
• Prevents build-up<br />
of mineral deposits<br />
• Lower pH inhibits<br />
bacterial growth<br />
between milkings<br />
• Reduces damage<br />
to rubber parts<br />
from high alkalinity<br />
and chlorine of<br />
wash cycle<br />
• Check<br />
manufacturer’s<br />
recommendation<br />
and post on<br />
cleaning chart<br />
7—4<br />
June 2010