Residential & Commercial <strong>Application</strong>s<br />
APPLICATION 2<br />
INSTALLATION<br />
RECOMMENDED<br />
PRODUCTS<br />
PROTECTING PELLA CASEMENT<br />
OR AWNING WINDOWS<br />
Recessed Contacts<br />
Pella casement and awning windows may have two separate pieces of glass or one<br />
Thermopane. It is very important, therefore, to take extra care when drilling the<br />
mounting holes to avoid the glass.<br />
Important: Pella recommends against mounting switches in sills due to possible<br />
damage from water. If you must drill into the sill, make sure you provide a solid,<br />
tight seal using RTV compound.<br />
Select position of switch in top of window frame if wires will run through attic, or<br />
in bottom of window if wires will run through basement.<br />
Drill 1/4" (0.635 cm) diameter x 1-1/4" (3.175 cm) deep hole in window sash.<br />
Insert magnet. If using wide gap switch, insert magnet with red end away from the<br />
switch end without wires.<br />
Drill 1/4" diameter hole in frame at approximately 15˚ toward inside of wall. Align<br />
switch hole center to within 1/4" of center of magnet.<br />
Insert switch (1055W placed close to the pivot point will allow for some<br />
ventilation).<br />
Test circuit, and glue switch and magnet in place.<br />
1015, 1015W, 1055, 1055W, 1125W<br />
Switch<br />
Magnet<br />
Wire access hole.<br />
Drill at 15°–30° from<br />
vertical.<br />
MAGNETIC CONTACTS<br />
Window Sash<br />
Window<br />
3.32