08.11.2014 Views

SENTROL Application notes - Alarms BC

SENTROL Application notes - Alarms BC

SENTROL Application notes - Alarms BC

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

.........................................................................................................................................................................<br />

Commercial <strong>Application</strong>s<br />

PROTECTING OVERHEAD OR CURTAIN DOORS<br />

APPLICATION 2<br />

INSTALLATION<br />

RECOMMENDED<br />

PRODUCTS<br />

Switch Mounted on Channel or Door Lip<br />

Installing security switch on channel or door lip, depending on door construction.<br />

Close door. Tape magnet in place with masking tape. Position magnet in recessed<br />

portion of slat as close to edge of door as possible. Mount with red end as shown.<br />

Roll up door, making sure magnet clears and does not interfere with operation of<br />

door. Close door.<br />

Attach magnet to door with screws.<br />

Attach wires to switch terminals. Attach switch to outside of long portion of<br />

bracket. Label must be right side up and facing away from door when bracket is<br />

mounted on channel.<br />

Attach bracket to channel with self-tapping screws.<br />

Important: Position bracket so that corner of door lip clears as door is opened<br />

and closed.<br />

Test proper operation of switch by closing and opening door.<br />

Dress wire leads with wire clamps and hook into alarm loop. Retest for operation<br />

and clearance.<br />

Switch — 1042TW; Magnet — 1923; Bracket — 1920-2; Clamps — 1931<br />

1923 Magnet<br />

1042T-W<br />

Switch<br />

Red End<br />

Caution: Be certain bracket provides<br />

adequate clearance for door lip.<br />

1931 Clamps<br />

1910-2<br />

Bracket<br />

MAGNETIC CONTACTS<br />

3.53