Industrial <strong>Application</strong>s<br />

EXPLOSIVE ATMOSPHERES<br />

APPLICATION<br />

INSTALLATION<br />

RECOMMENDED<br />

PRODUCTS<br />

Areas such as munitions depots, grain storage areas, and chemical plants can often<br />

involve explosive atmospheres. It is imperative, therefore, that PIRs used in such<br />

areas contribute no electrical signal or field that could cause ignition.<br />

Mount the 6197 Intrinsically Safe PIR in the hazardous area using either a sealed<br />

cable or sealed conduit fitting. Replace the standard lens with either of the other<br />

two lenses if needed.<br />

Mount the Barrier Box in the non-hazardous area next to the alarm panel.<br />

Run wire between the Barrier Box and the alarm panel terminals. Connect the<br />

ground lug on the bus bar inside the Barrier Box to an intrinsically safe ground<br />

using a 12 AWG wire or larger. Connect the chassis ground on the alarm panel to<br />

earth ground.<br />

Remove the front housing and install the jumpers in the PIR in the walk test<br />

mode. Select either one or two zone mode. Replace the front housing with the<br />

rubber gasket using four screws. Walk test the PIR. Install the Barrier Box lid.<br />

The Sentrol 6197 Intrinsically Safe PIR System is FM-approved and UL Listed<br />

for use in hazardous locations. For non-explosive applications that still require<br />

class I, Division 2, Groups A, B, C & D use the 6198 Non-incendive PIR.<br />

Cable or<br />

Conduit<br />

6197BB (Barrier Box)<br />

Ground Lug<br />

SPACE DETECTION<br />

6197 PIR<br />

+<br />

TAMP<br />

COM<br />

NC<br />

3<br />

4<br />

3<br />

4<br />

3<br />

4<br />

3<br />

4<br />

1<br />

2<br />

3<br />

4<br />

Barriers<br />

12 AWG or larger<br />

Alarm Panel<br />

Switching Module<br />

SUPPLY (RETURN)<br />

+12V<br />

+ SUPPLY (+12V NOM)<br />

Standard Lens Coverage<br />

Top View<br />

40'<br />

12.2m<br />

30'<br />

9.1m<br />

TAMP<br />

TAMP<br />

NC<br />

COM<br />

NO<br />

Cable or<br />

Conduit<br />

Intrinsically Safe<br />

Ground<br />

Earth<br />

Ground<br />

TAMPER LOOP<br />

+ TAMPER LOOP<br />

+ ALARM LOOP<br />

ALARM LOOP<br />

CHASSIS<br />

20'<br />

6.1m<br />

10'<br />

3.0m<br />

0<br />

0 10' 20' 30’ 40'<br />

3.0m 6.1m 9.1m 12.2m<br />

7'<br />

2.1m<br />

0<br />

Side View<br />

4°<br />

30 ° 15° Floor Line<br />

Additonal coverage patterns include vertical barrier and long range.<br />