Residential & Commercial <strong>Application</strong>s<br />
PROTECTING DOUBLE HUNG WINDOWS<br />
APPLICATION 1<br />
INSTALLATION<br />
RECOMMENDED<br />
PRODUCTS<br />
Recessed Installation in Top of Upper Window and<br />
Bottom of Lower Window<br />
Protecting double hung windows with recessed or surface-mounted magnetic<br />
contacts with regular or wide gap switches.<br />
Select position of magnet in window frame. Select position of switch in head or<br />
sill. Slightly over-drill holes for switch and magnet. Coat switch and magnet with<br />
RTV mounting compound. Insert switch and magnet in holes.<br />
Note: Wide gap switches are polarity sensitive. If switch uses bare magnet,<br />
observe correct polarity by mounting magnet with red end away from switch.<br />
Attach ohmmeter to leads and check for proper operation.<br />
Connect switch to loop.<br />
If desired, cover switch and magnet with wood filler to camouflage and to improve<br />
appearance.<br />
1015, 1055, 1059, 1065, 1075, 1125W, 1275W, RTV 1905<br />
End-to-End Recessed<br />
Switch<br />
Recessed Magnet<br />
Red End<br />
(If Wide Gap)<br />
MAGNETIC CONTACTS<br />
3.27