.........................................................................................................................................................................<br />
Commercial <strong>Application</strong>s<br />
24-HOUR PROTECTION OF METAL ENCLOSURES<br />
APPLICATION<br />
INSTALLATION<br />
RECOMMENDED<br />
PRODUCTS<br />
Protecting against unauthorized access to a control panel, bell box or any metal<br />
enclosure with a metal lid, eliminates the need for costly lining. Magnetic sensors<br />
provide protection against tampering, as through the key hole or lock mechanism,<br />
while shock sensors (see Glassbreak applications) provide protection against other<br />
types of forced entry. The magnetic contacts are connected to the control’s 24-hour<br />
loop.<br />
Tamper Protection<br />
Surface Mount: Use a Sentrol surface-mount, self-adhesive switch. With selfadhesive<br />
contacts, such as the 1035, locate switch on side or bottom of cabinet<br />
about 3/8" (0.95 cm) from front edge. Align magnet and mount. Test for operation<br />
with ohmmeter.<br />
Plunger Switch: Sentrol offers several plunger switches for tamper protection. All<br />
are hermetically sealed and reed actuated for positive operation on seldom-used<br />
enclosure openings.<br />
1035 self-adhesive magnetic contact; 3012 clips on 0.04" to 0.07" (0.10 to<br />
0.18 cm) thick sheet metal; 3012-1 clips on 0.08" to 0.12" (0.20 to 0.30 cm) thick<br />
sheet metal; 3025T with shunt capability for servicing.<br />
3/8"<br />
1035 Surface<br />
Mount<br />
Magnet<br />
3012 or<br />
3012-1 Clipon<br />
Plunger<br />
3025T<br />
Tamper<br />
Switch<br />
3011 3-hole<br />
Plunger<br />
MAGNETIC CONTACTS<br />
3011 3-hole<br />
Plunger<br />
Method 1<br />
Tamper Protection<br />
3.70