Residential & Commercial <strong>Application</strong>s<br />
PROTECTING DOUBLE HUNG WINDOWS<br />
APPLICATION 2<br />
INSTALLATION<br />
RECOMMENDED<br />
PRODUCTS<br />
Recessed Installation in Sides of Window<br />
This method of protecting double hung windows is recommended only when<br />
walls are open and readily accessible for running wires (i.e., during construction or<br />
remodeling). A finished wall will make this a very difficult job, requiring<br />
extremely awkward “fishing.”<br />
Requires perpendicular mounting of switch and magnet, and may require a wide<br />
gap between switch and magnet.<br />
Drill vertical hole in window frame for magnet. Coat magnet with RTV mounting<br />
compound and insert in hole.<br />
Pick position for switch. This will be determined by two requirements:<br />
1) Magnet must not be centered under switch. End of switch must be opposite<br />
the end of magnet (perpendicular) as shown.<br />
2) If wide gap switch is used, observe correct polarity by mounting magnet with<br />
red end away from the switch end with wires.<br />
Drill hole for switch and insert switch.<br />
Attach ohmmeter to leads. Close windows and test for correct operation.<br />
Connect switch to loop.<br />
1055, 1059, 1065, 1075, or same models in wide gap, RTV 1905<br />
MAGNETIC CONTACTS<br />