.........................................................................................................................................................................<br />

Commercial <strong>Application</strong>s<br />

PROTECTING OVERHEAD OR CURTAIN DOORS<br />

APPLICATION 4<br />

INSTALLATION<br />

RECOMMENDED<br />

PRODUCTS<br />

Using Magnapull<br />

A quick and easy way to protect overhead doors is to use the versatile<br />

Magnapull. There are no brackets to adapt and no drilling through thick steel<br />

tracks or channels. Magnapull is also ideal for overhead door applications where<br />

there is a lot of play in the door.<br />

Fasten cable using 1931 wire clamp so that if the switch is dropped it will not hit<br />

the floor.<br />

Mount the magnet housing at approximately a 20˚ angle from vertical to prevent<br />

switch damage if door is opened before switch is removed. The end user should be<br />

instructed to release the Magnapull switch before the door is opened to prevent<br />

damage to the switch.<br />

Position cable so there is slack between magnet housing and wire clamp.<br />

Test proper operation of switch by opening door.<br />

Switch — 2105; Clamp — 1931<br />

Wire Clamp<br />

MAGNETIC CONTACTS<br />

3.55