.........................................................................................................................................................................<br />

Residential <strong>Application</strong>s<br />

WHEN APPEARANCE IS PARAMOUNT<br />

APPLICATION<br />

INSTALLATION<br />

When adding a security system to an existing residence, the appearance of the<br />

system is often paramount in the mind of the homeowner. The homeowner will be<br />

concerned with sensor placement, the location of wires, location of the control<br />

panel, and how holes are drilled through existing walls.<br />

A unit that mounts close to the ceiling and in a corner is the least noticeable. It is<br />

also the most effective because it allows you to use a standard 90° lens, which<br />

gives you entire room coverage.<br />

• Choose a corner that is adjacent to the room’s entrance to get the best line of<br />

sight for the sensor. This is also the least obtrusive location.<br />

• Using the 6351 Sharpshooter DL, you will be able to mount as close to the<br />

ceiling as possible, making the unit even less noticeable. Pulling wires through<br />

the ceiling can be much easier and quicker than pulling them through walls.<br />

• Using the foam spacer, mount the bracket to the wall and connect the wires to<br />

the unit’s terminal block (see illustration). Then snap the cover in place.<br />

• Most rooms need only one-zone sensitivity. If the room is subject to<br />

temperature fluctuations or other instability, adjust the unit for two-zone<br />

sensitivity.<br />

• The DL incorporates an adjustable circuit board that allows you to mount flush<br />

to ceiling from 7' to 11' high.<br />

• Walk-test the unit to ensure correct operation.<br />

SPACE DETECTION<br />

RECOMMENDED<br />

PRODUCTS<br />

The DL 6351 DesignLine PIR combines an attractive, unobtrusive design with an<br />

easy-to-mount snap-on bracket. It can be mounted in a corner within 1/8" (3 mm)<br />

of the ceiling which makes it easier to install, saving you time and money.<br />

The 6351 DesignLine fits within 1/8”<br />

of the ceiling from 7 to11 feet high.<br />

Using the corner tool and bracket saves<br />

installation time.<br />

2.30