.........................................................................................................................................................................<br />

Commercial <strong>Application</strong>s<br />

PROTECTING OVERHEAD OR CURTAIN DOORS<br />

APPLICATION 8<br />

INSTALLATION<br />

RECOMMENDED<br />

PRODUCTS<br />

Buried Floor Switch<br />

Sometimes it is necessary to bury a magnetic contact in the floor, due to<br />

construction, or to permit fork lifts and other vehicles to pass in and out. A Sentrol<br />

switch has been designed for this installation. It features stainless steel for<br />

corrosion resistance and a wide gap operation for loose-fitting overhead doors.<br />

Select position of switch that will minimize amount of concrete to be chipped out.<br />

Install magnet on door and lay switch on floor. Test to make sure switch operates<br />

with at least 1" (2.54 cm) gap. If not 1", adjust magnet position.<br />

Chip concrete out approximately 1/2" deep x 1/2" wide (1.27 cm x 1.27 cm) for<br />

switch and cable.<br />

Lay switch in hole and test. Test— make sure of at least 1/2" extra gap.<br />

Pull cable through protective conduit and connect to switch.<br />

Test proper operation of switch by closing and opening door.<br />

Cover switch and cable with concrete patch.<br />

2227A<br />

Red End<br />

Bracket<br />

MAGNETIC CONTACTS<br />

Switch<br />

Magnet<br />

3.60