......................................................................................................................................................................... Introduction<br />

GENERAL SPECIFICATIONS<br />

Operating Specifications<br />

Switch Configurations:<br />

• Closed Loop Switch closed when magnet is in close proximity<br />

• Open Loop Switch open when magnet is in close proximity<br />

• S.P.D.T. Switch has common, open and closed sides<br />

• D.P.D.T. Two switches, each having common, open and closed sides<br />

Gap Distances<br />

Ratings are nominal and may vary ± 20%. Ratings are distance for switch to<br />

“make.” Break distance is approximately 1.1 to 1.5 times the “make” distance.<br />

Electrical Specifications<br />

Rating Closed Loop Open Loop SPDT DPDT<br />

Switching Voltage (Max.) 100V 30V 30V 30V<br />

Switching Current (Max.) 0.5 Amp 0.25 Amp 0.25 Amp 0.25 Amp<br />

Watts (Max.)(Volts x Amps) 7.5 Watts 3 Watts 3 Watts 3 Watts<br />

Warning: Each electrical rating is an individual maximum and cannot be exceeded!<br />

Example: <strong>Application</strong> at 100 VAC – 0.25 Amp would be 25 Watts and<br />

would exceed the rating of the switch.<br />

Environmental Specifications<br />

Temperature Range ............................................................................. -40˚F to 150˚F<br />

Shock ..................................................................................... 50 G’s @ 11 milliseconds<br />

Impact ...................... Withstands drop of 2" (5 cm) dia. steel ball from 30" (76.2 cm)<br />

Vibration ..................................................................................... 35 G’s @ 50-2000 Hz<br />

Internal Atmosphere ............................................................................ Dry Nitrogen<br />

MAGNETIC CONTACTS<br />