Residential & Commercial <strong>Application</strong>s<br />

APPLICATION<br />

INSTALLATION<br />

RECOMMENDED<br />

PRODUCTS<br />

PROTECTING WOOD DOOR THRESHOLDS<br />

WITH RECESSED CONTACTS<br />

For wood doors with aluminum thresholds, it is sometimes convenient to mount<br />

the magnet in the bottom of the door and the switch in the hollow space beneath<br />

the threshold.<br />

Note: Because of the distance between the magnet and switch, a Sentrol wide gap<br />

switch should be used.<br />

Select a recessed-mount wide gap switch.<br />

Drill horizontal hole for magnet in outside edge of door. Coat magnet with RTV<br />

mounting compound. Insert magnet in hole. If using a wide gap switch with bare<br />

magnet, insert with red end of magnet toward outside of door (switch is polarity<br />

sensitive).<br />

Remove threshold.<br />

Attach switch on inside of threshold with RTV mounting compound. Position it so<br />

it will be directly beneath (and parallel to) magnet when threshold is replaced.<br />

Replace threshold.<br />

Test switch with ohmmeter while opening and closing door.<br />

Connect switch to alarm loop.<br />

1055W, 1059W, 1065W, 1075W, RTV 1905.<br />

Door<br />

Red End<br />

Switch<br />

Magnet<br />

Aluminum Threshold<br />

MAGNETIC CONTACTS<br />

Figure 1. Wood Door Installation<br />

3.15