Commercial <strong>Application</strong>s<br />

PROTECTING OVERHEAD OR CURTAIN DOORS<br />

APPLICATION 7<br />

INSTALLATION<br />

RECOMMENDED<br />

PRODUCTS<br />

Switch Mounted on “Stop”<br />

Installing security switch on “stop” near top of overhead curtain type door.<br />

Close door. Tape magnet in place with masking tape. Position magnet in recessed<br />

portion of slat adjacent to door stop. Mount with red end as shown.<br />

Roll up door, making sure magnet clears and does not interfere with operation of<br />

door. Close door.<br />

Attach magnet to door with clamps, or with RTV mounting compound.<br />

Attach wires to switch terminals. Attach switch to inside of long portion of bracket.<br />

Label must be right side up and facing toward door when bracket is mounted on<br />

stop.<br />

Attach bracket to stop with self-tapping screws.<br />

Test proper operation of switch by closing and opening door.<br />

Dress wire leads with wire clamps and hook into alarm loop. Retest for operation<br />

and clearance.<br />

Switch — 1042TW; Magnet — 1923; Bracket — 1910-2; Clamps — 1931, RTV-1905.<br />

1923 Magnet<br />

1042T-W<br />

Switch<br />

1931 Clamps<br />

1910-2<br />

Bracket<br />

Red End<br />

MAGNETIC CONTACTS<br />

Door Stop<br />

3.59