Non-Standard Video Card<br />

Your PC may have a non-standard video card which has a<br />

“HIGH SPEED DECODE” or “FAST DECODE MODE” enabled<br />

which prevents any card from utilizing space in the upper<br />

memory blocks. Consult your video card manual, the<br />

manufacturer, or see your dealer to determine proper jumper<br />

settings for disabling this feature.<br />

Bus Speed<br />

Some BIOS’s allow non-standard AT bus speeds which are not<br />

compatible with AT cards, so that the CS8012 may show a<br />

MEMORY FAIL due to incorrect bus clock selection. The<br />

compatible AT standard bus speed is 8.3 MHz.<br />

The BIOS setting may vary with the manufacturer, however,<br />

so you need to find the appropriate line in the advanced<br />

chipset. The Phoenix BIOS setup is one example:<br />

System timing: AT clk select [Pclk/4]<br />

where Pclk is the Processor clock speed. On a 66 MHz<br />

system, Pclk is 33 MHz, so the setting should be:<br />

System timing: AT clk select [Pclk/4]<br />

(33MHz / 4) = 8.3 MHz<br />

Other BIOS’s may allow you to set the AT bus speed to 8<br />

MHz.<br />

Running GSINST from within Windows<br />

If you have been running GSINST from within Windows, try<br />

closing Windows and running GSINST directly from MS-DOS.<br />