4 Communications Issue 10/06<br />

4 Communications<br />

4.1 Establishing communications<br />

<strong>MICROM<strong>AS</strong>TER</strong> <strong>440</strong> ⇔ STARTER<br />

The following optional components are additionally required in order to establish<br />

communications between STARTER and <strong>MICROM<strong>AS</strong>TER</strong> <strong>440</strong>:<br />

‣ PC frequency inverter connecting set<br />

‣ BOP if the USS standard values (refer to Section 6.4.1 "Serial Interface (USS)")<br />

are changed in the <strong>MICROM<strong>AS</strong>TER</strong> <strong>440</strong> frequency inverter<br />

PC frequency inverter connecting set <strong>MICROM<strong>AS</strong>TER</strong> <strong>440</strong><br />

USS settings, refer to 6.4.1 "Serial<br />

Interface (USS)"<br />

STARTER<br />

Menu, Options --> Set PG/PC interface<br />

--> Select "PC COM-Port (USS)" --><br />

Properties --> Interface "COM1", select<br />

a baud rate<br />

NOTE<br />

The USS parameter settings in the<br />

<strong>MICROM<strong>AS</strong>TER</strong> <strong>440</strong> frequency inverter<br />

and the settings in STARTER must<br />

match!<br />

4.2 Establishing communications<br />

<strong>MICROM<strong>AS</strong>TER</strong> <strong>440</strong> ⇔ AOP<br />

‣ Communications between AOP and MM<strong>440</strong> are based on the USS protocol,<br />

analog to STARTER and MM<strong>440</strong>.<br />

‣ Contrary to the BOP, the appropriate communication parameters - both for the<br />

MM<strong>440</strong> as well as for AOP - should be set if the automatic interface detection<br />

was not carried-out (refer to Table 4-1).<br />

‣ Using the optional components, the AOP can be connected to the<br />

communication interfaces (refer to Table 4-1).<br />

Table 4-1<br />

MM<strong>440</strong> parameters<br />

- baud rate<br />

- bus address<br />

AOP parameters<br />

- baud rate<br />

- bus address<br />

Options<br />

- direct connection<br />

- indirect connection<br />

AOP at the BOP link<br />

P2010[1]<br />

–<br />

P8553<br />

–<br />

No option necessary<br />

BOP/AOP door mounting kit<br />

(6SE6400-0PM00-0AA0)<br />

AOP at the COM link<br />

P2010[0]<br />

P2011<br />

P8553<br />

P8552<br />

Not possible<br />

AOP door mounting kit<br />

(6SE6400-0MD00-0AA0)<br />

<strong>MICROM<strong>AS</strong>TER</strong> <strong>440</strong><br />

24 Operating Instructions (Compact)